Automated bone property analysis using corrected in vivo dental cone-beam CT data of human wrists

被引:0
|
作者
Klintstrom, Benjamin [1 ]
Spangeus, Anna [2 ,3 ,4 ]
Malusek, Alexandr [5 ]
Synek, Alexander [6 ]
Woisetschlager, Mischa [4 ,7 ,8 ]
Pahr, Dieter [6 ]
Klintstrom, Eva [4 ,7 ,8 ]
机构
[1] KTH Royal Inst Technol, Dept Biomed Engn & Hlth Syst, Huddinge, Sweden
[2] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Diagnost & Specialist Med, Linkoping, Sweden
[3] Linkoping Univ Hosp, Dept Acute Internal Med & Geriatr, Linkoping, Sweden
[4] CMIV, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[5] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
[6] TU Wien, Inst Lightweight Design & Struct Biomech, Gumpendorfer Str 7, A-1060 Vienna, Austria
[7] Linkoping Univ, Dept Radiol Linkoping, Linkoping, Sweden
[8] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Diagnost & Specialist Med, Linkoping, Sweden
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
CBCT; DXA; Bone structure; Segmentation; Structure analysis; DISTAL RADIUS; COMPUTED-TOMOGRAPHY; HR-PQCT; FRACTURE; ADOLESCENTS; DENSITY; QUALITY; VOLUME; FE;
D O I
10.1038/s41598-024-75222-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fracture liaison services are essential to mitigate underdiagnosis and undertreatment of osteoporosis-related fractures. However, it often suffers from limited access to dual-energy X-ray absorptiometry (DXA) or high-resolution peripheral quantitative CT equipment. This in vivo study of 21 patients aims to evaluate the feasibility of dental cone beam CT (dCBCT) to analyse bone properties of human wrists, comparing with DXA and finite element (FE) analysis. dCBCT grey-scale values were transformed to HU using a phantom containing materials with known HU values. Strong correlations were found between bone mineral content (BMC) from dCBCT and DXA (r = 0.78 to 0.84, p < 0.001), as well as between BMC from dCBCT FE-predicted stiffness (r = 0.91) and maximum force (r = 0.93), p < 0.001. BMC values from dCBCT were higher than DXA measurements (2.34 g vs. 1.5 g, p < 0.001). Cortical thickness strongly correlated to bone mineral density (BMD) from dCBCT (r = 0.83, p < 0.001). No statistically significant correlations were found between trabecular bone microstructure and FE predictions. The results indicate the feasibility to analyse osteoporosis related bone properties of human wrists from corrected dCBCT data. The dCBCT values of BMD and BMC were strongly correlated with DXA.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Automatic analysis algorithm for acquiring standard dental and mandibular shape data using cone-beam computed tomography
    Jae Joon Hwang
    Sang-Sun Han
    Chena Lee
    Yun-Hoa Jung
    Scientific Reports, 8
  • [22] Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
    He, Rong-Ting
    Tu, Ming-Gene
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Wu, Jay
    Hsu, Jui-Ting
    BMC MEDICAL IMAGING, 2019, 19 (1)
  • [23] Automatic analysis algorithm for acquiring standard dental and mandibular shape data using cone-beam computed tomography
    Hwang, Jae Joon
    Han, Sang-Sun
    Lee, Chena
    Jung, Yun-Hoa
    SCIENTIFIC REPORTS, 2018, 8
  • [24] Investigation of dental cone-beam CT pixel data and a modified method for conversion to Hounsfield unit (HU)
    Magill, Dennise
    Beckmann, Natalie
    Felice, Marc A.
    Yoo, Thomas
    Luo, Minou
    Mupparapu, Mel
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (02)
  • [25] 3D morphometric analysis of the human incudomallear complex using clinical cone-beam CT
    Soons, Joris A. M.
    Danckaers, Femke
    Keustermans, William
    Huysmans, Toon
    Sijbers, Jan
    Casselman, Jan W.
    Dirckx, Joris J. J.
    HEARING RESEARCH, 2016, 340 : 79 - 88
  • [26] Preliminary Study of Optimization-Based Image Reconstruction from Dental Cone-beam CT Data
    Zhang, Z.
    Han, X.
    Bian, J.
    Kusnoto, B.
    Sidky, E. Y.
    Pan, X.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [27] Diagnosis of in vivo vertical root fracture using deep learning on cone-beam CT images
    Ziyang Hu
    Dantong Cao
    Yanni Hu
    Baixin Wang
    Yifan Zhang
    Rong Tang
    Jia Zhuang
    Antian Gao
    Ying Chen
    Zitong Lin
    BMC Oral Health, 22
  • [28] Helical CT reconstruction from wide cone-beam angle data using ART
    Carvalho, BM
    Herman, GT
    XVI BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, PROCEEDINGS, 2003, : 363 - 370
  • [29] 3D IN VIVO DOSIMETRY USING MEGAVOLTAGE CONE-BEAM CT AND EPID DOSIMETRY
    van Elmpt, Wouter
    Nusten, Sebastiaan
    Petit, Steven
    Munheer, Ben
    Lambin, Philippe
    Dekker, Andre
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1580 - 1587
  • [30] Diagnosis of in vivo vertical root fracture using deep learning on cone-beam CT images
    Hu, Ziyang
    Cao, Dantong
    Hu, Yanni
    Wang, Baixin
    Zhang, Yifan
    Tang, Rong
    Zhuang, Jia
    Gao, Antian
    Chen, Ying
    Lin, Zitong
    BMC ORAL HEALTH, 2022, 22 (01)