Automated bone property analysis using corrected in vivo dental cone-beam CT data of human wrists

被引:0
|
作者
Klintstrom, Benjamin [1 ]
Spangeus, Anna [2 ,3 ,4 ]
Malusek, Alexandr [5 ]
Synek, Alexander [6 ]
Woisetschlager, Mischa [4 ,7 ,8 ]
Pahr, Dieter [6 ]
Klintstrom, Eva [4 ,7 ,8 ]
机构
[1] KTH Royal Inst Technol, Dept Biomed Engn & Hlth Syst, Huddinge, Sweden
[2] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Diagnost & Specialist Med, Linkoping, Sweden
[3] Linkoping Univ Hosp, Dept Acute Internal Med & Geriatr, Linkoping, Sweden
[4] CMIV, Ctr Med Image Sci & Visualizat, Linkoping, Sweden
[5] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
[6] TU Wien, Inst Lightweight Design & Struct Biomech, Gumpendorfer Str 7, A-1060 Vienna, Austria
[7] Linkoping Univ, Dept Radiol Linkoping, Linkoping, Sweden
[8] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Diagnost & Specialist Med, Linkoping, Sweden
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
CBCT; DXA; Bone structure; Segmentation; Structure analysis; DISTAL RADIUS; COMPUTED-TOMOGRAPHY; HR-PQCT; FRACTURE; ADOLESCENTS; DENSITY; QUALITY; VOLUME; FE;
D O I
10.1038/s41598-024-75222-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fracture liaison services are essential to mitigate underdiagnosis and undertreatment of osteoporosis-related fractures. However, it often suffers from limited access to dual-energy X-ray absorptiometry (DXA) or high-resolution peripheral quantitative CT equipment. This in vivo study of 21 patients aims to evaluate the feasibility of dental cone beam CT (dCBCT) to analyse bone properties of human wrists, comparing with DXA and finite element (FE) analysis. dCBCT grey-scale values were transformed to HU using a phantom containing materials with known HU values. Strong correlations were found between bone mineral content (BMC) from dCBCT and DXA (r = 0.78 to 0.84, p < 0.001), as well as between BMC from dCBCT FE-predicted stiffness (r = 0.91) and maximum force (r = 0.93), p < 0.001. BMC values from dCBCT were higher than DXA measurements (2.34 g vs. 1.5 g, p < 0.001). Cortical thickness strongly correlated to bone mineral density (BMD) from dCBCT (r = 0.83, p < 0.001). No statistically significant correlations were found between trabecular bone microstructure and FE predictions. The results indicate the feasibility to analyse osteoporosis related bone properties of human wrists from corrected dCBCT data. The dCBCT values of BMD and BMC were strongly correlated with DXA.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Is application of a quantitative CT technique helpful for quantitative measurement of bone density using dental cone-beam CT?
    Nishikawa, Keiichi
    Kousuge, Yuuji
    Sano, Tsukasa
    ORAL RADIOLOGY, 2016, 32 (01) : 9 - 13
  • [2] Predicting Cortical Bone Strength from DXA and Dental Cone-Beam CT
    Hsu, Jui-Ting
    Chen, Ying-Ju
    Tsai, Ming-Tzu
    Lan, Howard Haw-Chang
    Cheng, Fu-Chou
    Chen, Michael Y. C.
    Wang, Shun-Ping
    PLOS ONE, 2012, 7 (11):
  • [3] Is application of a quantitative CT technique helpful for quantitative measurement of bone density using dental cone-beam CT?
    Keiichi Nishikawa
    Yuuji Kousuge
    Tsukasa Sano
    Oral Radiology, 2016, 32 : 9 - 13
  • [4] Automated CNN-Based Tooth Segmentation in Cone-Beam CT for Dental Implant Planning
    Lee, S.
    Woo, S.
    Yu, J.
    Seo, J.
    Lee, J.
    Lee, C.
    IEEE ACCESS, 2020, 8 : 50507 - 50518
  • [5] Dose calculation on megavoltage cone-beam CT images corrected for cupping and missing data artifacts
    Aubry, J.
    Morin, O.
    Faddegon, B.
    Nunna, C.
    Beaulieu, L.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2342 - 2342
  • [6] Automatic Extraction of Mandibular Nerve and Bone from Cone-Beam CT Data
    Kainmueller, Dagmar
    Lamecker, Hans
    Seim, Heiko
    Zinser, Max
    Zachow, Stefan
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT II, PROCEEDINGS, 2009, 5762 : 76 - +
  • [7] Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT
    Ibrahim, Norliza
    Parsa, Azin
    Hassan, Bassam
    van der Stelt, Paul
    Rahmat, Rabiah A.
    Ismail, Siti M.
    Aartman, Irene H. A.
    BMC ORAL HEALTH, 2021, 21 (01)
  • [8] The assessment of trabecular bone parameters and cortical bone strength: A comparison of micro-CT and dental cone-beam CT
    Hsu, Jui-Ting
    Wang, Shun-Ping
    Huang, Heng-Li
    Chen, Ying-Ju
    Wu, Jay
    Tsai, Ming-Tzu
    JOURNAL OF BIOMECHANICS, 2013, 46 (15) : 2611 - 2618
  • [9] Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT
    Norliza Ibrahim
    Azin Parsa
    Bassam Hassan
    Paul van der Stelt
    Rabiah A. Rahmat
    Siti M. Ismail
    Irene H. A. Aartman
    BMC Oral Health, 21
  • [10] Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets
    Ibrahim, Norliza
    Parsa, Azin
    Hassan, Bassam
    van der Stelt, Paul
    Aartman, Irene H. A.
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 941 - 945