IMU-Based Real-Time Biofeedback Wristband With Automatic Sensor-to-Segment Calibration for Arm Swing Training

被引:0
|
作者
Fan, Bingfei [1 ]
Chen, Jie [1 ]
Tan, Chao [1 ]
Zhu, Yifeng [1 ]
Liu, Tao [2 ]
Li, Qingguo [3 ]
Cai, Shibo [4 ]
Jiang, Tianyu [5 ]
机构
[1] Zhejiang University of Technology, College of Mechanical Engineering, Hangzhou,310023, China
[2] Zhejiang University, State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Hangzhou,310027, China
[3] Queen's University, Department of Mechanical and Materials Engineering, Kingston,ON,K7L 3N6, Canada
[4] Zhejiang University of Technology, College of Mechanical Engineering, The Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Hangzhou,310023, China
[5] Chinese PLA General Hospital, The Second Medical Center and National Clinical Research Center for Geriatric Diseases, National Key Laboratory of Kidney Diseases, Department of Rehabilitation Medicine, Beijing,100000, China
基金
中国国家自然科学基金;
关键词
Angular velocity - Exercise equipment - Forward error correction - Image segmentation - Mean square error;
D O I
10.1109/JSEN.2025.3529416
中图分类号
学科分类号
摘要
Arm swing during walking is significant as it enhances gait stability and reduces energy expenditure. Reduced arm swing in patients with Parkinson's disease (PD) or the elderly causes poor mobility and higher fall risk. This article develops an IMU-based real-time biofeedback wristband with an automatic sensor-to-segment calibration algorithm for arm swing training. The real-time algorithm detects key frames and calculates the sensor-to-segment alignment transformation, then monitors arm swing motion, and provides vibration feedback when insufficient arm swing is detected. Validation experiments were performed to assess the accuracies of arm swing angle, angular velocity estimations, and the effectiveness of real-time biofeedback. Seventeen subjects wore wristbands and optical markers on their arms while performing slow, normal, and fast walking on a treadmill. Arm swing angle, angular velocity, and range of motion were extracted with and without the proposed calibration method. An additional wristband manually aligned with the forearm was used for comparison and an optical motion capture (OMC) system was utilized for reference. For the proposed method with automatic calibration, the root-mean-square errors (RMSEs) of the estimated continuous swing angle and angular velocity were 2.1° and 12.8°/s, respectively, which were 46% and 58% of those estimated with the manually aligned wristband. In real-time feedback experiments, subjects exhibited a notable increase in arm swing amplitude given the stimulus from vibration feedback. The developed wristband could serve as an effective training and easy-to-use device, which has the potential for PD patients to increase their arm swing amplitude during walking. © 2001-2012 IEEE.
引用
收藏
页码:9780 / 9789
相关论文
共 50 条
  • [41] A wireless sensor system for validation of real-time automatic calibration of groundwater transport models (vol 82, pg 1859, 2009)
    Loden, Philip
    Han, Qi
    Porta, Lisa
    Illangasekare, Tissa
    Jayasumana, Anura P.
    JOURNAL OF SYSTEMS AND SOFTWARE, 2010, 83 (04) : 710 - 710
  • [42] FPGA-Based Real-Time Implementation of Detection Algorithm for Automatic Traffic Surveillance Sensor Network
    Wojcikowski, Marek
    Zaglewski, Robert
    Pankiewicz, Bogdan
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2012, 68 (01): : 1 - 18
  • [43] FPGA-Based Real-Time Implementation of Detection Algorithm for Automatic Traffic Surveillance Sensor Network
    Marek Wójcikowski
    Robert Żaglewski
    Bogdan Pankiewicz
    Journal of Signal Processing Systems, 2012, 68 : 1 - 18
  • [44] Real-Time Orientation-Invariant Magnetic Localization and Sensor Calibration Based on Closed-Form Models
    Shen, Hui-Min
    Hu, Liang
    Qin, Long-Hui
    Fu, Xin
    IEEE MAGNETICS LETTERS, 2015, 6
  • [45] Wearable Sensor-Based Real-Time Sonification of Motion and Foot Pressure in Dance Teaching and Training
    Grosshauser, T.
    Blaesing, B.
    Spieth, C.
    Hermann, T.
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 2012, 60 (7-8): : 580 - 589
  • [46] Wearable sensor-based real-time sonification of motion and foot pressure in dance teaching and training
    Grosshauser, T.
    Bläsing, B.
    Spieth, C.
    Hermann, T.
    AES: Journal of the Audio Engineering Society, 2012, 60 (7-8): : 580 - 589
  • [47] A real-time multi view gait-based automatic gender classification system using kinect sensor
    Azhar, Muhammad
    Ullah, Sehat
    Raees, Muhammad
    Rahman, Khaliq Ur
    Rehman, Inam Ur
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 82 (08) : 11993 - 12016
  • [48] A real-time multi view gait-based automatic gender classification system using kinect sensor
    Muhammad Azhar
    Sehat Ullah
    Muhammad Raees
    Khaliq Ur Rahman
    Inam Ur Rehman
    Multimedia Tools and Applications, 2023, 82 : 11993 - 12016
  • [49] A Real-Time Automatic Plate Recognition System Based on Optical Character Recognition and Wireless Sensor Networks for ITS
    Dalarmelina, Nicole do Vale
    Teixeira, Marcio Andrey
    Meneguette, Rodolfo, I
    SENSORS, 2020, 20 (01)
  • [50] A Sensor Based Monitoring System for Real-Time Quality Control: Semi-Automatic Arc Welding Case Study
    Hamzeh, Reza
    Thomas, Luke
    Polzer, Jan
    Xu, Xun W.
    Heinzel, Holger
    30TH INTERNATIONAL CONFERENCE ON FLEXIBLE AUTOMATION AND INTELLIGENT MANUFACTURING (FAIM2021), 2020, 51 : 201 - 206