Study on novel neutron irradiation without beam shaping assembly in Boron Neutron Capture Therapy

被引:2
|
作者
Verdera, Antonia [1 ]
Praena, Javier [1 ]
机构
[1] Univ Granada, Dept Atom Mol & Nucl Phys, Granada 18072, Spain
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
BNCT; Neutron production; IAEA quality factors; Dose; Therapeutic range; CROSS-SECTIONS; REACTION-RATES; ACCELERATOR; BNCT; OPTIMIZATION; CALIBRATION; UNIVERSITY;
D O I
10.1038/s41598-024-73458-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Boron Neutron Capture Therapy (BNCT) is performed using high-intensity neutron sources; however, the energy of the primary neutrons is too high for direct patient irradiation. Thus, neutron moderation is mandatory and is performed using a device known as a Beam Shaping Assembly (BSA). Due to the differences in flux and energy spectra between neutron sources, each facility needs a dedicated BSA design, whether it is based on a nuclear reactor or, more recently, on an accelerator. Since moderation involves the loss of neutrons, typically by a factor of 1000, it is necessary to generate a very high flux before neutrons pass through the BSA. We propose a novel approach that eliminates the necessity of a BSA, BSA-free, by generating neutrons suitable in flux and energy for direct patient irradiation through the \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${}<^>{45}$$\end{document}Sc(p,n)\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${}<^>{45}$$\end{document}Ti reaction using near-threshold protons. Our findings demonstrate that all IAEA quality factors for BNCT can be met with existing proton accelerators. Additionally, figures of merit studied provide similar results compared to real BNCT facilities. This breakthrough opens up new avenues in BNCT, among others, the control of the neutron penetration within the human body by small changing in the proton energy. Also, it is expected simplified accelerator-based facilities in terms of manufacturing and maintenance and operation. This work is a study based on experimental data and Monte Carlo simulations. Technical challenges and safety are addressed in Discussion section. This novel proposal is under evaluation as patent.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Microdosimetric spectra of the THOR neutron beam for boron neutron capture therapy
    Hsu, FY
    Tung, CJ
    Watt, DE
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (02) : 121 - 126
  • [22] A PROTOTYPE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON-CAPTURE THERAPY
    NOONAN, DJ
    RUSSELL, JL
    BRUGGER, RM
    MEDICAL PHYSICS, 1986, 13 (02) : 211 - 216
  • [23] Boron neutron capture therapy (BNCT):: Implications of neutron beam and boron compound characteristics
    Wheeler, FJ
    Nigg, DW
    Capala, J
    Watkins, PRD
    Vroegindeweij, C
    Auterinen, I
    Seppälä, T
    Bleuel, D
    MEDICAL PHYSICS, 1999, 26 (07) : 1237 - 1244
  • [24] Novel polymers for boron neutron capture therapy
    不详
    EXPERT OPINION ON THERAPEUTIC PATENTS, 1996, 6 (03) : 275 - 279
  • [25] DNA Double-strand Breaks Induced byFractionated Neutron Beam Irradiation for Boron Neutron Capture Therapy
    Kinashi, Yuko
    Yokomizo, Natsuya
    Takahashi, Sentaro
    ANTICANCER RESEARCH, 2017, 37 (04) : 1681 - 1685
  • [26] A modified fast neutron therapy beam for boron neutron capture enhanced fast neutron therapy (BNCEFNT)
    Kota, C
    Maughan, RL
    Burmeister, J
    Forman, JD
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A496 - A500
  • [27] Study of epithermal neutron columns for boron neutron capture therapy
    Oka, Y
    Akiyama, M
    An, S
    PROGRESS IN NUCLEAR ENERGY, 1998, 32 (1-2) : 61 - 70
  • [28] ENHANCEMENT OF THE EPITHERMAL NEUTRON BEAM USED FOR BORON NEUTRON-CAPTURE THERAPY
    LIU, HYB
    BRUGGER, RM
    GREENBERG, DD
    RORER, DC
    HU, JP
    HAUPTMAN, HM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1149 - 1156
  • [29] Toward a final design for the Birmingham boron neutron capture therapy neutron beam
    Allen, DA
    Beynon, TD
    Green, S
    James, ND
    MEDICAL PHYSICS, 1999, 26 (01) : 77 - 82
  • [30] Epithermal neutron beam dosimetry with thermoluminescence dosemeters for boron neutron capture therapy
    Aschan, C
    Toivonen, M
    Savolainen, S
    Seppälä, T
    Auterinen, I
    RADIATION PROTECTION DOSIMETRY, 1999, 81 (01) : 47 - 56