Optimal sizing and performance assessment of stand-alone PV systems using optimum hybrid sizing strategy

被引:0
|
作者
Abed, Mohamad [1 ]
Reddy, Amarendra [1 ]
Jyothsna, T. R. [1 ]
Mohammed, Nabil [2 ]
机构
[1] Andhra Univ, Coll Engn, Dept Elect Engn, Visakhapatnam 530003, Andhra Pradesh, India
[2] King Abdullah Univ Sci & Technol, Comp Elect & Math Sci & Engn CEMSE Div, Thuwal 23955, Makkah, Saudi Arabia
关键词
Stand-alone PV systems (SAPVS); Renewable energy sources (RES); Global solar atlas (GSA); State of charge (SOC); Performance assessment; Variable active load; Designing month; DOD; PSH; PHOTOVOLTAIC SYSTEMS; BATTERY; METHODOLOGY; MODEL; HOUSE; COST;
D O I
10.1016/j.rineng.2024.103793
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A hybrid strategy for the optimal sizing of stand-alone photovoltaic systems (SAPVS) is proposed in this article, with an emphasis on the worst-case photovoltaic (PV) power generation scenario. Since individual optimization methods for SAPVS sizing aim to address multipurpose challenges, the hybrid approach effectively manages such complexities. This strategy is developed by integrating three stages. These are (i) Initial exploration stage, (ii) Implementation of integrated calculation methods, and (iii) Rigorous performance assessment of the designed system. The initial exploration stage provides a preliminary understanding to determine the worst-case PV power generation at a predetermined installation location. In this stage, data are obtained from the Global Solar Atlas (GSA) platform and PVsyst software reports, and critical parameters such as Peak Sun Hour (PSH), designing month, annual optimal tilt, and azimuth angles are defined. In the Implementation of integrated calculation methods, intuitive and numerical calculation methods are integrated into the methodology, supported by a feedback-closed loop for iterative refinement and comparison. In the performance assessment stage, the designed SAPVS undergoes a rigorous performance evaluation to ensure compliance with technical requirements before the practical implementation on the site. Detailed system component simulations, including electro-magnetic transients (EMT) in MATLAB/Simulink and PVsyst, are employed. The performance assessment utilizes real-time data for December, identified as the worst-case month for PV power generation in the initial exploration stage. Actual data for a residential load in Latakia, Syria, are used to validate the design. The preliminary exploration stage significantly accelerates the performance assessment. For instance, EMT simulations in MATLAB/Simulink require one day to complete a single case (December). Without the exploration stage, simulations for all 12 months would exceed 12 days. Results confirm that the designed SAPVS meets technical requirements, with steady-state and dynamic performances assessed through graphical analyses of electrical characteristics, power flow, and output curves.
引用
收藏
页数:27
相关论文
共 50 条
  • [11] Optimal Sizing for Stand-Alone Hybrid PV-WIND Power Supply System Using PSO
    Suchitra, D.
    Jegatheesan, R.
    Reddy, M. Umamaheswara
    Deepika, T. J.
    SWARM, EVOLUTIONARY, AND MEMETIC COMPUTING, PT I (SEMCCO 2013), 2013, 8297 : 617 - 629
  • [12] Optimal sizing of stand-alone and grid-connected solar PV systems in Bangladesh
    Das B.K.
    International Journal of Energy for a Clean Environment, 2020, 21 (02) : 107 - 124
  • [13] Optimal Sizing Stand-alone PV Systems Based on The Observed Extremes Over a Threshold
    Chen, Shin-Guang
    TENCON 2010: 2010 IEEE REGION 10 CONFERENCE, 2010, : 84 - 89
  • [14] Optimum unit sizing of stand-alone PV-WT-Battery hybrid system components using Jaya
    Khan, Asif
    Javaid, Nadeem
    Javaid, Sakeena
    2018 IEEE 21ST INTERNATIONAL MULTI-TOPIC CONFERENCE (INMIC), 2018,
  • [15] Robust optimal sizing of a hybrid energy stand-alone system
    Billionnet, Alain
    Costa, Marie-Christine
    Poirion, Pierre-Louis
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2016, 254 (02) : 565 - 575
  • [16] Sizing stand-alone photovoltaic systems
    Balouktsis, A.
    Karapantsios, T. D.
    Antoniadis, A.
    Paschaloudis, D.
    Bezergiannidou, A.
    Bilalis, N.
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2006, 2006
  • [17] Sizing the battery for stand-alone systems
    Misak, Stanislav
    Prokop, Lukas
    Kacor, Petr
    PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 596 - 599
  • [18] Optimal Sizing of Stand-alone PV System using Artificial Bee Colony Algorithm
    Yusri, Md
    Khalil, Ashraf
    Peng, Ang Swee
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2021, 13 (07): : 54 - 67
  • [19] Optimal sizing of stand-alone photovoltaic systems in residential buildings
    Okoye, Chiemeka Onyeka
    Solyali, Oguz
    ENERGY, 2017, 126 : 573 - 584
  • [20] Optimal sizing of a stand-alone photovoltaic system
    Bouabdallah, Ahmed
    Bourguet, Salvy
    Olivier, Jean-Christophe
    Machmoum, Mohamed
    2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2013, : 543 - 548