Influence of blade installation angle spanwise distribution on the energy characteristics of mining contra-rotating axial flow fan

被引:0
|
作者
Chen, Yongping [1 ,2 ]
Liu, Ronghua [2 ]
Liu, Chunyu [3 ]
Chen, Shiqiang [1 ,2 ]
Wu, Shixian [3 ]
Liu, Dong [4 ]
Li, Yangyi [5 ]
Zhou, Xuan [6 ]
机构
[1] Hunan Univ Sci & Technol, Sanya Inst, Sanya 572024, Peoples R China
[2] Hunan Univ Sci & Technol, Sch Resource & Environm & Safety Engn, Xiangtan 411201, Peoples R China
[3] Guilin Univ Aerosp Technol, Sch Energy Engn & Bldg Environm, Guilin 541004, Peoples R China
[4] Guangxi Commun Investment Grp Co Ltd, Nanning 530025, Peoples R China
[5] Guangxi Commun Design Grp Co Ltd, Nanning 530025, Peoples R China
[6] China Tobacco Anhui Ind Co Ltd, Chuzhou Cigarette Factory, Chuzhou 239000, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
基金
中国国家自然科学基金;
关键词
Mine ventilation; Mining counter-rotating axial flow fan; Blade installation angle; Energy loss; Entropy production theory; LOCAL ENTROPY PRODUCTION; TURBULENT SHEAR FLOWS; EFFICIENCY;
D O I
10.1038/s41598-025-90797-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
As the global demand for energy conservation increases, achieving efficient energy conversion in fans has become a significant challenge in the field of mine ventilation. To investigate the influence of the blade installation angle distribution in the spanwise direction on the energy characteristics of mining counter-rotating axial flow fan, three blade optimization schemes were proposed in this paper. The internal flow field of the fan was obtained by numerical simulation and experimental methods. Based on the entropy production theory, the correlation between energy loss and flow field parameters was established, thus achieving the quantitative assessment of energy loss. The research findings indicate significant differences in energy characteristics before and after blade optimization, with scheme OP1 (when the optimization case 1 is applied to both the front impeller and rear impeller) demonstrating superior performance. Compared to the original fan, scheme OP1 efficiency and total pressure increase by 1.1% and 1.3%, respectively, under 1.0 QBEP condition (QBEP is flow rate at the best efficiency point). Furthermore, under 1.2 QBEP condition, improvements reach 3.1% and 4.7%, respectively. The improvement in the efficiency of scheme OP1 is mainly attributed to the reduction in the energy loss rate induced by turbulent dissipation within the rear impeller and downstream domain. Notably, distinct differences in the energy loss rates of fan extension pipe for different schemes, the energy loss rate of scheme OP1 is reduced by 24.6% compared to that of the original fan under 1.2 QBEP condition.
引用
收藏
页数:22
相关论文
共 41 条
  • [31] Blade rows interaction in contra-rotating axial flow pump designed with different rotational speed concept
    Cao, L. L.
    Watanabe, S.
    Imanishi, T.
    Yoshimura, H.
    Furukawa, A.
    6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52
  • [32] Influence of axial spacing on stall development of FBCDZ-10-No20 mode contra-rotating fan
    Chen Q.
    Xu Y.
    Guo W.
    Zhang Z.
    Meitan Kexue Jishu/Coal Science and Technology (Peking), 2023, 51 (06): : 229 - 236
  • [33] Identification and classification of operating flow regimes and prediction of stall in a contra-rotating axial fan using machine learning
    Kumar, A.
    Manas, M. P.
    Pradeep, A. M.
    AERONAUTICAL JOURNAL, 2022, 126 (1302): : 1351 - 1369
  • [34] UNDERSTANDING UNSTEADY FLOW BEHAVIOUR IN A LOW ASPECT RATIO CONTRA-ROTATING AXIAL FAN UNDER RADIALLY DISTORTED INFLOW
    Payyappalli, Manas Madasseri
    Pradeep, A. M.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 2A, 2019,
  • [35] NUMERICAL INVESTIGATION OF INFLUENCE OF ROTOR-ROTOR GAP ON PERFORMANCES OF CONTRA-ROTATING AXIAL FLOW PUMP
    Cao, Linlin
    Watanabe, Satoshi
    Furukawa, Akinori
    Wu, Dazhuan
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 1, 2015,
  • [36] UNDERSTANDING THE FLOW BEHAVIOR IN A LOW HUB-TIP RATIO, HIGH ASPECT RATIO CONTRA-ROTATING AXIAL FAN STAGE
    Mistry, Chetan S.
    Pradeep, A. M.
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE 2012, 2012, : 51 - 62
  • [37] Simulation on performance and acoustic characteristics with deeply abnormal installation angle of single blade in a variable pitch axial fan
    Li, Chunxi
    Yin, Pan
    Ye, Xuemin
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2012, 32 (35): : 122 - 129
  • [38] Internal Flow Characteristics of a Variable Pitch Axial Fan Under Abnormal Installation Angles of a Single Blade
    Ye, Xuemin
    Li, Chunxi
    Wang, Songling
    Li, Jun
    ADVANCED SCIENCE LETTERS, 2011, 4 (6-7) : 2164 - 2169
  • [39] Research on Two-Way Contra-Rotating Axial-Flow Pump-Turbine with Various Blade Angles in Pump Mode
    Chen, Yiming
    An, Ce
    Zhang, Rongyong
    Fu, Qiang
    Zhu, Rongsheng
    PROCESSES, 2023, 11 (05)
  • [40] On high efficiency operation of contra-rotating axial flow pump with rotational speed control toward effective energy saving
    Cao, L. L.
    Watanabe, S.
    Imanishi, T.
    Momosaki, S.
    Furukawa, A.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15