Experimental analysis of a pilot plant in Organic Rankine Cycle configuration with regenerator and thermal energy storage (TES-RORC)

被引:0
|
作者
Guerron, Gonzalo [1 ,2 ]
Nicolalde, Juan Francisco [1 ,3 ,4 ]
Martinez-Gomez, Javier [1 ,4 ]
Davila, Paul [5 ]
Velasquez, Carlos [2 ,5 ,6 ]
机构
[1] Univ Alcala, Escuela Politecn, Dept Teoria Senal & Comunicac, Area Ingn Mecan, Madrid 28805, Spain
[2] Inst Invest Geol & Energet, Quito 170518, Ecuador
[3] Univ Int Ecuador UIDE, Fac Ciencias Tecn, Quito 170411, Ecuador
[4] Univ Int SEK, Fac Ingn & Ciencias Aplicadas, Albert Einstein S-N & 5th, Quito 170302, Ecuador
[5] Univ Alicante, Dept Appl Math, Alicante, Spain
[6] Univ Cent Ecuador, Modal Linea, Quito, Ecuador
关键词
Organic Rankine cycle; Phase change material; Novec; 649; Thermal energy storage; WASTE HEAT-RECOVERY; TWIN-SCREW EXPANDER; FLUID SELECTION; EXERGY ANALYSIS; ORC; TEMPERATURE; OPTIMIZATION; PERFORMANCE; SYSTEM;
D O I
10.1016/j.energy.2024.132964
中图分类号
O414.1 [热力学];
学科分类号
摘要
Applying thermal energy storage in a Regenerative Organic Rankine Cycle system is a possible combination of energy storage for renewable and waste energy sources. This research presents an experimental analysis of a regenerative organic Rankine cycle pilot plant, incorporating a thermal energy storage chamber based on a phase change materials to obtain thermal inertia in the system. The primary heat source is the residual heat of combustion gases at a temperature of approximately 320 degrees C coming from a generating set that operates within a thermal power generation plant. The prototype uses a twin-screw expander modified to work as a turbine. Novec 649 was used as the working fluid which is an organic compound. The experimental evaluation of the regenerative organic Rankine cycle with thermal energy storage has been carried out through energy and exergetic efficiency analysis to verify the operation of the pilot plant. Values of 13.2 % were obtained for the exergetic efficiency and 2.67 % for the global efficiency of the cycle, with a maximum expander work of 11.8 kW. It was demonstrated that the thermal energy storage system provides energy in response to the plant's operating inertia for 17.5 min, sufficient time for the gradual shutdown of the plant equipment, maintaining the working power of the regenerative organic Rankine cycle.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Analysis of waste heat recovery of power plant thermal system based on organic Rankine cycle
    Wang Lei
    Zhang Ruiqing
    Jiang Yang
    2018 5TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2018, : 144 - 147
  • [32] Analysis of Liquid Air Energy Storage System with Organic Rankine Cycle and Heat Regeneration System
    Umyshev, Dias Raybekovich
    Osipov, Eduard Vladislavovich
    Kibarin, Andrey Anatolievich
    Korobkov, Maxim Sergeyevich
    Petukhov, Yuriy Viktorovich
    SUSTAINABILITY, 2024, 16 (13)
  • [33] Levelised Cost of Storage (LCOS) analysis of liquid air energy storage system integrated with Organic Rankine Cycle
    Tafone, Alessio
    Ding, Yulong
    Li, Yongliang
    Xie, Chunping
    Romagnoli, Alessandro
    ENERGY, 2020, 198
  • [34] Optimal design and operation of an Organic Rankine Cycle (ORC) system driven by solar energy with sensible thermal energy storage
    Yu, Haoshui
    Helland, Henrik
    Yu, Xingji
    Gundersen, Truls
    Sin, Gurkan
    ENERGY CONVERSION AND MANAGEMENT, 2021, 244 (244)
  • [35] Energy analysis of a trigeneration plant based on solid oxide fuel cell and organic Rankine cycle
    Al-Sulaiman, Fahad A.
    Dincer, Ibrahim
    Hamdullahpur, Feridun
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) : 5104 - 5113
  • [36] Parametric Energy and Economic Analysis of Modified Combined Cycle Power Plant with Vapor Absorption and Organic Rankine Cycle
    Moiz, Abdul
    Shahzaib, Malik
    Memon, Abdul Ghafoor
    Kumar, Laveet
    Assad, Mamdouh El Haj
    Energy Engineering: Journal of the Association of Energy Engineering, 2024, 121 (11): : 3095 - 3120
  • [37] Experimental evaluation at pilot plant scale of multiple PCMs (cascaded) vs. single PCM configuration for thermal energy storage
    Peiro, Gerard
    Gasia, Jaume
    Miro, Laia
    Cabeza, Luisa F.
    RENEWABLE ENERGY, 2015, 83 : 729 - 736
  • [38] Analysis of two heat storage integrations for an Organic Rankine Cycle Parabolic trough solar power plant
    Chacartegui, R.
    Vigna, Leo
    Becerra, J. A.
    Verda, V.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 125 : 353 - 367
  • [39] Experimental and Simulation Analysis of Siloxane Mixtures Used in Organic Rankine Cycle with Thermal Stability Limits
    Wang, Wenhuan
    Tian, Lei
    Shi, Lin
    Dai, Xiaoye
    PROCESSES, 2023, 11 (07)
  • [40] Investigation of organic Rankine cycle integrated with double latent thermal energy storage for engine waste heat recovery
    Yu, Xiaoli
    Li, Zhi
    Lu, Yiji
    Huang, Rui
    Roskilly, Anthony Paul
    ENERGY, 2019, 170 : 1098 - 1112