Optically Validated Microvascular Phantom for Super-Resolution Ultrasound Imaging

被引:0
|
作者
Raad, Jaime Parra [1 ]
Lock, Daniel [1 ]
Liu, Yi-Yi [1 ]
Solomon, Mark [1 ]
Peralta, Laura [2 ]
Christensen-Jeffries, Kirsten [1 ]
机构
[1] Kings Coll London, Dept Biomed Engn & Imaging Sci, London WC2R 2LS, England
[2] Kings Coll London, Dept Surg & Intervent Engn, London WC2R 2LS, England
基金
英国医学研究理事会;
关键词
Phantoms; Optical imaging; Optical device fabrication; Optical variables control; Optical variables measurement; Imaging; Ultrasonic imaging; Three-dimensional displays; Optical diffraction; Optical recording; Contrast enhanced ultrasound (US) imaging; microfluid chip; microvascular phantom; super-resolution US (SRUS) imaging; tissue-mimicking material; US localization microscopy; US phantom; vascular phantom; TISSUE-MIMICKING PHANTOM; MODEL;
D O I
10.1109/TUFFC.2024.3484770
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Super-resolution ultrasound (SRUS) visu-Microvascular Phantom alises microvasculature beyond the ultrasound diffraction limit (wavelength (lambda)/2) by localising and tracking spatially isolated microbubble contrast agents. SRUS phantoms typically consist of simple tube structures, where diameter channels below 100 mu m are not available. Furthermore, these phantoms are generally fragile and unstable, have limited ground truth validation, and their simple structure limits the evaluation of SRUS algorithms. To aid SRUS development, robust and durable phantoms with known and physiologically relevant microvasculature are needed for repeatable SRUS testing. This work proposes a method to fabricate durable microvascular phantoms that allow optical gauging for SRUS validation. The methodology used a microvasculature negative print embedded in a Polydimethylsiloxane to fabricate a microvascular phantom. Branching microvascular phantoms with variable microvascular density were demonstrated with optically validated vessel diameters down to similar to 60 mu m(lambda/5.8; lambda=similar to 350 mu m ). SRUS imaging was performed and validated with optical measurements. The average SRUS error was 15.61 mu m(lambda/22) with a standard deviation error of 11.44 mu m. The average error decreased to 7.93 mu m(lambda/44) once the number of localised microbubbles surpassed 1000 per estimated diameter. In addition, the less than 10% variance of acoustic and optical properties and the mechanical toughness of the phantoms measured a year after fabrication demonstrated their long-term durability. This work presents a method to fabricate durable and optically validated complex microvascular phantoms which can be used to quantify SRUS performance and facilitate its further development.
引用
收藏
页码:1833 / 1843
页数:11
相关论文
共 50 条
  • [41] Localization with deep learning networks for super-resolution ultrasound imaging
    Brown, Katherine
    Redfern, Arthur D.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [42] Super-resolution ultrasound in peripheral nerve blood flow imaging
    Zhang, Jiabin
    Zhu, Yaqiong
    Li, Nan
    Dong, Feihong
    Yin, Jingyi
    Wang, Yuexiang
    Luo, Yukun
    Zhang, Jue
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [43] Temporal Super-resolution of Ultrasound Imaging Using Matrix Completion
    Hosseinpour, Mina
    Behnam, Hamid
    Shojaeifard, Maryam
    ULTRASONIC IMAGING, 2020, 42 (03) : 115 - 134
  • [44] Effects of Aberration on Super-Resolution Ultrasound Imaging using Microbubbles
    Peralta, Laura
    Hajnal, Joseph, V
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [45] Ultrasound Super-Resolution Imaging of Neonatal Cerebral Vascular Reorganization
    Schwarz, Simone
    Denis, Louise
    Nedoschill, Emmanuel
    Buehler, Adrian
    Danko, Vera
    Hilger, Alina C.
    Nunez, Francisco Brevis
    Duerr, Nikola R.
    Schlunz-Hendann, Martin
    Brassel, Friedhelm
    Felderhoff-Mueser, Ursula
    Reutter, Heiko
    Woelfle, Joachim
    Juengert, Jorg
    Dohna-Schwake, Christian
    Bruns, Nora
    Regensburger, Adrian P.
    Couture, Olivier
    Mandelbaum, Henriette
    Knieling, Ferdinand
    ADVANCED SCIENCE, 2025,
  • [46] Advancements in Three-Dimensional Super-Resolution Ultrasound Imaging
    Ghosh, Debabrata
    Hoyt, Kenneth
    JOURNAL OF ULTRASOUND IN MEDICINE, 2025,
  • [47] Three-dimensional super-resolution ultrasound imaging of chicken embryos - A validation framework for analysis of microvascular morphology
    Oezdemir, Ipek
    Mohr-Allen, Shelby
    Peak, Kara E.
    Varner, Victor
    Hoyt, Kenneth
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [48] Assessing resolution in super-resolution imaging
    Demmerle, Justin
    Wegel, Eva
    Schermelleh, Lothar
    Dobbie, Ian M.
    METHODS, 2015, 88 : 3 - 10
  • [49] Recent progress on super-resolution imaging and correlative super-resolution microscopy
    Lin Dan-Ying
    Qu Jun-Le
    ACTA PHYSICA SINICA, 2017, 66 (14)
  • [50] Super-resolution retinal imaging using optically reassigned scanning laser ophthalmoscopy
    Theodore B. DuBose
    Francesco LaRocca
    Sina Farsiu
    Joseph A. Izatt
    Nature Photonics, 2019, 13 : 257 - 262