Impact on Image Quality and Diagnostic Performance of Dual-Layer Detector Spectral CT for Pulmonary Subsolid Nodules: Comparison With Hybrid and Model-Based Iterative Reconstruction

被引:1
|
作者
Ding, Li [1 ]
Li, Xiaomei [1 ]
Lin, Jie [1 ]
Deng, Shuting [1 ]
Chen, Mingwang [1 ]
Deng, Weiwei [2 ]
Xu, Yikai [1 ]
Chen, Zhao [1 ]
Yan, Chenggong [1 ]
机构
[1] Southern Med Univ, Dept Med Imaging Ctr, Nanfang Hosp, 1838 Guangzhou Ave North, Guangzhou 510515, Guangdong, Peoples R China
[2] Philips Healthcare, Clin & Tech Solut, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
pulmonary subsolid nodule; dual-layer detector spectral CT; iterative reconstruction; Electron density mapping; quantitative analysis; ENERGY COMPUTED-TOMOGRAPHY;
D O I
10.1097/RCT.0000000000001640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the image quality and diagnostic performance of pulmonary subsolid nodules on conventional iterative algorithms, virtual monoenergetic images (VMIs), and electron density mapping (EDM) using a dual-layer detector spectral CT (DLSCT). Methods: This retrospective study recruited 270 patients who underwent DLSCT scan for lung nodule screening or follow-up. All CT examinations with subsolid nodules (pure ground-glass nodules [GGNs] or part-solid nodules) were reconstructed with hybrid and model-based iterative reconstruction, VMI at 40, 70, 100, and 130 keV levels, and EDM. The CT number, objective image noise, signal-to-noise ratio, contrast-to-noise ratio, diameter, and volume of subsolid nodules were measured for quantitative analysis. The overall image quality, image noise, visualization of nodules, artifact, and sharpness were subjectively rated by 2 thoracic radiologists on a 5-point scale (1 = unacceptable, 5 = excellent) in consensus. The objective image quality measurements, diameter, and volume were compared among the 7 groups with a repeated 1-way analysis of variance. The subjective scores were compared with Kruskal-Wallis test. Results: A total of 198 subsolid nodules, including 179 pure GGNs, and 19 part-solid nodules were identified. Based on the objective analysis, EDM had the highest signal-to-noise ratio (164.71 +/- 133.60; P < 0.001) and contrast-to-noise ratio (227.97 +/- 161.96; P < 0.001) among all image sets. Furthermore, EDM had a superior mean subjective rating score (4.80 +/- 0.42) for visualization of GGNs compared to other reconstructed images (all P < 0.001), although the model-based iterative reconstruction had superior subjective scores of overall image quality. For pure GGNs, the measured diameter and volume did not significantly differ among different reconstructions (both P > 0.05). Conclusions: EDM derived from DLSCT enabled improved image quality and lesion conspicuity for the evaluation of lung subsolid nodules compared to conventional iterative reconstruction algorithms and VMIs.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 50 条
  • [41] Value of dual-layer spectral detector computed tomography in the diagnosis of benign/malignant solid solitary pulmonary nodules and establishment of a prediction model
    Xie, Xiaodong
    Liu, Kaifang
    Luo, Kai
    Xu, Youtao
    Zhang, Lei
    Wang, Meiqin
    Shen, Wenrong
    Zhou, Zhengyang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [42] Initial Evaluation of Model-Based Iterative CT Reconstruction Using Standard Image Quality Phantoms
    Gingold, E.
    Dave, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [43] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2464 - 2473
  • [44] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    European Radiology, 2018, 28 : 2464 - 2473
  • [45] Evaluation of image quality and radiation dose saving comparing knowledge model-based iterative reconstruction on 80-kV CT pulmonary angiography (CTPA) with hybrid iterative reconstruction on 100-kV CT
    Ippolito, Davide
    De Vito, Andrea
    Franzesi, Cammillo Talei
    Riva, Luca
    Pecorelli, Anna
    Corso, Rocco
    Crespi, Andrea
    Sironi, Sandro
    EMERGENCY RADIOLOGY, 2019, 26 (02) : 145 - 153
  • [46] Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom
    Hyo-Jin Kang
    Jeong Min Lee
    Sang Min Lee
    Hyun Kyung Yang
    Ri Hyeon Kim
    Ju Gang Nam
    Aruna Karnawat
    Joon Koo Han
    BMC Medical Imaging, 19
  • [47] Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom
    Kang, Hyo-Jin
    Lee, Jeong Min
    Lee, Sang Min
    Yang, Hyun Kyung
    Kim, Ri Hyeon
    Nam, Ju Gang
    Karnawat, Aruna
    Han, Joon Koo
    BMC MEDICAL IMAGING, 2019, 19 (01)
  • [48] Evaluation of the depiction ability of the microanatomy of the temporal bone in quarter-detector CT Model-based iterative reconstruction vs hybrid iterative reconstruction
    Kurokawa, Ryo
    Maeda, Eriko
    Mori, Harushi
    Amemiya, Shiori
    Sato, Jiro
    Ino, Kenji
    Torigoe, Rumiko
    Abe, Osamu
    MEDICINE, 2019, 98 (24)
  • [49] Effects of radiation dose levels and spectral iterative reconstruction levels on the accuracy of iodine quantification and virtual monochromatic CT numbers in dual-layer spectral detector CT: an iodine phantom study
    Lu, Xiaomei
    Lu, Zaiming
    Yin, Jiandong
    Gao, Yuying
    Chen, Xingbiao
    Guo, Qiyong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (02) : 188 - 200
  • [50] Image Quality in Children with Low-Radiation Chest CT Using Adaptive Statistical Iterative Reconstruction and Model-Based Iterative Reconstruction
    Sun, Jihang
    Peng, Yun
    Duan, Xiaomin
    Yu, Tong
    Zhang, Qifeng
    Liu, Yong
    Hu, Di
    PLOS ONE, 2014, 9 (05):