Impact on Image Quality and Diagnostic Performance of Dual-Layer Detector Spectral CT for Pulmonary Subsolid Nodules: Comparison With Hybrid and Model-Based Iterative Reconstruction

被引:1
|
作者
Ding, Li [1 ]
Li, Xiaomei [1 ]
Lin, Jie [1 ]
Deng, Shuting [1 ]
Chen, Mingwang [1 ]
Deng, Weiwei [2 ]
Xu, Yikai [1 ]
Chen, Zhao [1 ]
Yan, Chenggong [1 ]
机构
[1] Southern Med Univ, Dept Med Imaging Ctr, Nanfang Hosp, 1838 Guangzhou Ave North, Guangzhou 510515, Guangdong, Peoples R China
[2] Philips Healthcare, Clin & Tech Solut, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
pulmonary subsolid nodule; dual-layer detector spectral CT; iterative reconstruction; Electron density mapping; quantitative analysis; ENERGY COMPUTED-TOMOGRAPHY;
D O I
10.1097/RCT.0000000000001640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the image quality and diagnostic performance of pulmonary subsolid nodules on conventional iterative algorithms, virtual monoenergetic images (VMIs), and electron density mapping (EDM) using a dual-layer detector spectral CT (DLSCT). Methods: This retrospective study recruited 270 patients who underwent DLSCT scan for lung nodule screening or follow-up. All CT examinations with subsolid nodules (pure ground-glass nodules [GGNs] or part-solid nodules) were reconstructed with hybrid and model-based iterative reconstruction, VMI at 40, 70, 100, and 130 keV levels, and EDM. The CT number, objective image noise, signal-to-noise ratio, contrast-to-noise ratio, diameter, and volume of subsolid nodules were measured for quantitative analysis. The overall image quality, image noise, visualization of nodules, artifact, and sharpness were subjectively rated by 2 thoracic radiologists on a 5-point scale (1 = unacceptable, 5 = excellent) in consensus. The objective image quality measurements, diameter, and volume were compared among the 7 groups with a repeated 1-way analysis of variance. The subjective scores were compared with Kruskal-Wallis test. Results: A total of 198 subsolid nodules, including 179 pure GGNs, and 19 part-solid nodules were identified. Based on the objective analysis, EDM had the highest signal-to-noise ratio (164.71 +/- 133.60; P < 0.001) and contrast-to-noise ratio (227.97 +/- 161.96; P < 0.001) among all image sets. Furthermore, EDM had a superior mean subjective rating score (4.80 +/- 0.42) for visualization of GGNs compared to other reconstructed images (all P < 0.001), although the model-based iterative reconstruction had superior subjective scores of overall image quality. For pure GGNs, the measured diameter and volume did not significantly differ among different reconstructions (both P > 0.05). Conclusions: EDM derived from DLSCT enabled improved image quality and lesion conspicuity for the evaluation of lung subsolid nodules compared to conventional iterative reconstruction algorithms and VMIs.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 50 条
  • [1] Ultra-low dose dual-layer detector spectral CT for pulmonary nodule screening: image quality and diagnostic performance
    Ding, Li
    Chen, Mingwang
    Li, Xiaomei
    Wu, Yuting
    Li, Jingxu
    Deng, Shuting
    Xu, Yikai
    Chen, Zhao
    Yan, Chenggong
    INSIGHTS INTO IMAGING, 2025, 16 (01):
  • [2] Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging
    Doerner, Jonas
    Hauger, Myriam
    Hickethier, Tilman
    Byrtus, Jonathan
    Wybranski, Christian
    Hokamp, Nils Grosse
    Maintz, David
    Haneder, Stefan
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 52 - 58
  • [3] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822
  • [4] Comparison of the effects of model-based iterative reconstruction and filtered back projection algorithms on software measurements in pulmonary subsolid nodules
    Cohen, Julien G.
    Kim, Hyungjin
    Park, Su Bin
    van Ginneken, Bram
    Ferretti, Gilbert R.
    Lee, Chang Hyun
    Goo, Jin Mo
    Park, Chang Min
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3266 - 3274
  • [5] Comparison of the effects of model-based iterative reconstruction and filtered back projection algorithms on software measurements in pulmonary subsolid nodules
    Julien G. Cohen
    Hyungjin Kim
    Su Bin Park
    Bram van Ginneken
    Gilbert R. Ferretti
    Chang Hyun Lee
    Jin Mo Goo
    Chang Min Park
    European Radiology, 2017, 27 : 3266 - 3274
  • [6] Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT
    Hyungjin Kim
    Chang Min Park
    Seong Ho Kim
    Sang Min Lee
    Sang Joon Park
    Kyung Hee Lee
    Jin Mo Goo
    European Radiology, 2014, 24 : 2700 - 2708
  • [7] Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT
    Kim, Hyungjin
    Park, Chang Min
    Kim, Seong Ho
    Lee, Sang Min
    Park, Sang Joon
    Lee, Kyung Hee
    Goo, Jin Mo
    EUROPEAN RADIOLOGY, 2014, 24 (11) : 2700 - 2708
  • [8] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Hui Lu
    Kaifang Liu
    Huan Zhao
    Yongqiang Wang
    Bo Shi
    Scientific Reports, 14
  • [9] Dual-layer detector spectral CT-based machine learning models in the differential diagnosis of solitary pulmonary nodules
    Lu, Hui
    Liu, Kaifang
    Zhao, Huan
    Wang, Yongqiang
    Shi, Bo
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [10] COMPARISON OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR™) AND MODEL-BASED ITERATIVE RECONSTRUCTION (VEO™) FOR PAEDIATRIC ABDOMINAL CT EXAMINATIONS: AN OBSERVER PERFORMANCE STUDY OF DIAGNOSTIC IMAGE QUALITY
    Hultenmo, Maria
    Caisander, Hakan
    Mack, Karsten
    Thilander-Klang, Anne
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 107 - 114