Seismic performance of the extended end-plate high-strength steel beam-to-column connections after fire

被引:0
|
作者
Xu, Jixiang [1 ]
Zhang, Yifan [1 ]
机构
[1] Lanzhou Univ Technol, Dept Civil Engn, Lanzhou 730050, Peoples R China
基金
中国国家自然科学基金;
关键词
EEP-HSSBC connections; Seismic performance; Post-fire cyclic loading; Parametric analysis; BEHAVIOR;
D O I
10.1016/j.istruc.2024.107786
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the seismic performance of the extended end-plate high-strength steel beam-to-column (EEP-HSSBC) connections after fire. The accuracy and effectiveness of the computational model are validated using existing experimental results. Considering actual engineering parameters, a parametric analysis is conducted to evaluate the seismic performance of the EEP-HSSBC connections after fire. The parameters include the ratio of column width to thickness (alpha), column height-to-thickness ratio (R), beam width-to-thickness ratio (gamma), beam height-to-thickness ratio (8), and beam stiffener length-to-thickness ratio (ti). 25 computational models are established to examine the seismic performance, stiffness degradation, ductility, and energy dissipation capacity of these beam to column connections under post-fire cyclic loading. Results indicate that increases in parameters gamma and 8 enhance both the stiffness and bearing capacity of the beam to column connections. Temperature significantly affects the stiffness, stress distribution, energy dissipation capacity, and bearing capacity of the beam to column connections. The findings can provide a theoretical basis for evaluating the performance of such connections under post-fire seismic action and offer reference and technical support for their design.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Experimental investigation of force-distribution in high-strength bolts in extended end-plate connections
    Abdalla, K. M.
    Abu-Farsakh, G. A. R.
    Barakat, S. A.
    STEEL AND COMPOSITE STRUCTURES, 2007, 7 (02): : 87 - 103
  • [42] Structural behaviour of stainless steel double extended end-plate beam-to-column joints under monotonic loading
    Gao, J. D.
    Yuan, H. X.
    Du, X. X.
    Hu, X. B.
    Theofanous, M.
    THIN-WALLED STRUCTURES, 2020, 151
  • [43] Hysteresis Envelope Model of Double Extended End-Plate Bolted Beam-to-Column Joint
    Krolo, Paulina
    Grandic, Davor
    BUILDINGS, 2021, 11 (11)
  • [44] Effect of sfiffene on behaviour of beam to column extended end-plate connection in fire
    Hao, Shu-Ying
    Dong, Jin-Hao
    Ye, Jin-Duo
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (08): : 152 - 155
  • [45] Column flange strength at moment end-plate connections
    Curtis, Larry E., 1600, (26):
  • [46] Test on seismic behaviors of stainless steel bolted extended end-plate beam-column joints
    Zheng, Baofeng
    Wu, Dianhan
    Wang, Jiachang
    Shu, Ganping
    THIN-WALLED STRUCTURES, 2024, 196
  • [47] Experimental and numerical investigation on seismic performance of extended stiffened end-plate joints with reduced beam section using high strength steel
    Liang, Gang
    Lu, Zhihan
    Guo, Hongchao
    Liu, Yunhe
    Yang, Dixiong
    Li, Shen
    Pan, Xiuzhen
    THIN-WALLED STRUCTURES, 2021, 169
  • [48] Behaviour and design of high-strength steel beam-to-column joints
    Li, Dongxu
    Uy, Brian
    Wang, Jia
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (03): : 303 - 317
  • [49] Experimental and numerical investigation on seismic performance of extended stiffened end-plate joints with reduced beam section using high strength steel
    Liang, Gang
    Lu, Zhihan
    Guo, Hongchao
    Liu, Yunhe
    Yang, Dixiong
    Li, Shen
    Pan, Xiuzhen
    Liang, Gang (lg20854007@163.com), 1600, Elsevier Ltd (169):
  • [50] Numerical study on the behaviour of end-plate beam-to-column connections under lateral impact loading
    Al-Rifaie, Ali
    Al-Husainy, Alaa S.
    Shanbara, Hayder K.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2020, 10 (02) : 150 - 173