Enhancing the Thermal Efficiency of Parabolic Trough Collectors by Using Annular Receivers for Low-Enthalpy Steam Generation

被引:0
|
作者
Aquino-Santiago, Zuriel [1 ]
Aguilar, J. O. [2 ]
Becerra-Nunez, Guillermo [2 ,3 ]
Jaramillo, O. A. [4 ]
机构
[1] Univ Nacl Autonoma Mexico, Posgrad Ingn Energia, Priv Xochicalco s-n, Temixco 62580, Morelos, Mexico
[2] Univ Autonoma Estado Quintana Roo, Div Ciencias Ingn & Tecnol, Blvd Bahia S-N, Chetmal 77019, Quintana Roo, Mexico
[3] Consejo Nacl Human Ciencias & Tecnol, Investigadoras Investigadores Mexico, Ave Insurgentes 1582, Ciudad De Mexico 03940, Mexico
[4] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
concentrated solar energy; parabolic trough collector; Second Law analysis; low enthalpy processes; annular flow receiver; HEAT-TRANSFER;
D O I
10.3390/pr12122653
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Parabolic Trough Collectors (PTCs) are a well-established technology for efficiently generating hot water and low-enthalpy steam. For instance, PTCs can be used in steam power systems to drive small Organic Rankine Cycles (ORCs). This study evaluated the thermal efficiency of a PTC equipped with a receiver tube featuring a concentric annular cross-section. This receiver design consists of a tube with a concentric rod inside, forming an annular gap through which the working fluid flows. A thermodynamic model was developed to assess the PTC's thermal efficiency in hot water and low-enthalpy steam applications. The evaluation considered the First and Second Laws of Thermodynamics, factoring in environmental losses. The model included a bare receiver tube with three-rod diameters-3/8, 1/2, and 3/4 inches-and a range of volumetric flow rates from 1 to 6 L per minute. The results showed improved heat transfer with the annular cross-section receiver compared to a conventional circular one, particularly at lower flow rates of 1 and 2 L per minute. The highest increase in thermal efficiency was observed with the 3/4-inch rod at a flow rate of 1 L per minute, where the maximum efficiency reached 40%.
引用
收藏
页数:25
相关论文
共 50 条
  • [32] Machine learning predictions for enhancing solar parabolic trough collector efficiency with corrugated tube receivers
    Venkatesaperumal, R.
    Jafar, K. syed
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2024, 49 (02):
  • [33] Thermal plant based on parabolic trough collectors for industrial process heat generation in Morocco
    El Ghazzani, Badreddine
    Martinez Plaza, Diego
    Ait El Cadi, Radia
    Ihlal, Ahmed
    Abnay, Brahim
    Bouabid, Khalid
    RENEWABLE ENERGY, 2017, 113 : 1261 - 1275
  • [34] Machine learning predictions for enhancing solar parabolic trough collector efficiency with corrugated tube receivers
    R VENKATESAPERUMAL
    K SYED JAFAR
    Sādhanā, 49
  • [35] Enhancing thermal efficiency of parabolic trough collectors using SiO2 nanofluids: a comparative study of particle size impact on solar energy harvesting
    Sivaraman, Prabhakaran
    Kolandaivel, Visagavel
    Rajendran, Silambarasan
    Dhairiyasamy, Ratchagaraja
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 9155 - 9172
  • [36] Thermo-Hydraulic Analysis of Parabolic trough Collectors for Direct Steam Generation with Relap5
    Valenzuela, Loreto
    Saynes, Jacobo
    Moya, Sara L.
    TECNOLOGIA Y CIENCIAS DEL AGUA, 2016, 7 (03) : 75 - 91
  • [37] Mathematical model for direct steam generation in parabolic trough collectors with Compound-Wall Receiver.
    Palacios, AV
    Salgado, RA
    López, AS
    Menzer, MM
    PROCEEDINGS OF THE 1998 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE, 1998, : 271 - 275
  • [38] Alternative Approach for Thermo-Hydraulic Modeling of Direct Steam Generation in Parabolic Trough Solar Collectors
    Gonzalez-Mora, Eduardo
    Duran-Garcia, M. Dolores
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (05)
  • [39] Impact of pressure losses in small-sized parabolic-trough collectors for direct steam generation
    Lobon, David H.
    Valenzuela, Loreto
    ENERGY, 2013, 61 : 502 - 512
  • [40] Nonlinear distributed parameter model and dynamic characteristics of parabolic trough direct steam generation solar collectors
    College of Energy and Environment, Southeast University, Nanjing 210096, Jiangsu Province, China