A novel dual-wheel air-conditioning system operating strategy in different seasons

被引:0
|
作者
Zhang, Hui [1 ]
Fang, Zhicong [1 ]
Zhang, Xuemei [1 ]
Yang, Shangkuan [1 ]
Qian, Zheng [1 ]
Chen, Zhiguang [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 201804, Peoples R China
关键词
Dual-wheel Air-conditioning System; Polymer Desiccant Wheel; Operating Strategy; DESICCANT COOLING SYSTEM; PERFORMANCE; PROPOSAL; ENERGY;
D O I
10.1016/j.enbuild.2024.114812
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The application of solid desiccant air-conditioning systems can significantly reduce building energy consumption. Previous studies have focused on innovating the integration of solid desiccant air-conditioning systems (DACS) to improve dehumidification performance in summer. In this paper, a novel DACS is proposed, which can humidify the supply air in winter based on satisfying the dehumidification demands in summer. It can satisfy the year-round humidity requirements of domestic housing with significant savings in humidification costs. Furthermore, the operating strategy of the novel DACS is proposed, particularly for winter humidification conditions. It is adaptable as well as cost-effective compared to traditional operating strategies. The dehumidification/humidification capacity of the core component, polymer desiccant wheel, and the variation of temperature rise/temperature drop are investigated under different variations of parameters, including air temperature, air humidity, air volume flow rate, and wheel speed. The results show that with the increase of supply air mass flow from 0.6 kg/s to 1.9 kg/s, the power consumption of the system only increases by 9.5 kW. In winter, when the supply air temperature decreases from 8 degrees C to 1 degrees C, the power consumption increases by 7.2 kW, but in summer, when the temperature of the supply air increases by 7 degrees C, the power consumption of the system decreases by 7.0 kW. The power consumption of the system varies greatly when the humidity of the supply air is less than 17 g/kg, conversely, the power consumption of the system showed a negative trend. The analysis demonstrates the effective performance of the proposed system under varying climatic conditions.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Selection of an air-conditioning system for a hospital
    Said, Salem A.
    Hassan, M.A.
    Alnajjar, Rogeh K.
    Energy Engineering: Journal of the Association of Energy Engineering, 1993, 90 (03): : 24 - 34
  • [42] RESPONSES TO AIR-CONDITIONING SYSTEM NOISE
    KO, NWM
    HO, WF
    UN, WK
    JOURNAL OF SOUND AND VIBRATION, 1978, 57 (04) : 595 - 602
  • [43] AIR-CONDITIONING SYSTEM FOR A TWISTING MILL
    不详
    MELLIAND TEXTILBERICHTE INTERNATIONAL TEXTILE REPORTS, 1977, 58 (08): : 625 - 625
  • [44] CONTROLLER FOR VEHICLE AIR-CONDITIONING SYSTEM
    OOI, TH
    LAU, KT
    LIM, CH
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1990, 36 (02) : 66 - 75
  • [45] AIR-CONDITIONING BY TWIN DUCT SYSTEM
    不详
    REFRIGERATION AND AIR CONDITIONING, 1973, 76 (905): : 61 - &
  • [46] CGPC: An application to an air-conditioning system
    Petrault, C
    Mehdi, D
    Trigeassou, JC
    PROCEEDINGS OF THE 1997 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1997, : 1951 - 1952
  • [48] A New Central Air-Conditioning System Control Strategy based on Prediction Model
    Shou, Qingyun
    PROCEEDINGS OF 2010 3RD IEEE INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND INFORMATION TECHNOLOGY (ICCSIT 2010), VOL 6, 2010, : 479 - 482
  • [49] SURVEY OF DESIGN PRACTICES OF HOSPITAL OPERATING-ROOM AIR-CONDITIONING AND VENTILATION SYSTEM
    OVIATT, VR
    AMERICAN JOURNAL OF PUBLIC HEALTH AND THE NATIONS HEALTH, 1961, 51 (12): : 1902 - +
  • [50] The Optimal Control Strategy for Chilled Water System in Central Air-conditioning Systems
    Li, Ao
    Wang, Fulin
    Li, Rui
    Zhu, Binruo
    Huang, Dan
    Chen, Gang
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 8150 - 8155