Real-Time Ultrasonic Measurement Method of Dynamic Film Thickness and Influencing Factors of Measurement Blind Area

被引:0
|
作者
Sun W. [1 ]
Liang P. [1 ,2 ]
Guo F. [1 ]
Kong L. [1 ]
Jiang F. [1 ]
Bai Q. [1 ]
Liu X. [1 ]
机构
[1] School of Mechanical & Automotive Engineering, Qingdao University of Technology, Shandong, Qingdao
[2] Key Laboratory of Industrial Fluid Energy Conservation and Pollution Control, Ministry of Education, Qingdao University of Technology, Shandong, Qingdao
来源
Mocaxue Xuebao/Tribology | 2024年 / 44卷 / 02期
基金
中国国家自然科学基金;
关键词
blind area; lubrication film thickness; on line measurement; simulation calculation; ultrasonic wave technology;
D O I
10.16078/j.tribology.2022248
中图分类号
学科分类号
摘要
Lubrication film thickness measurement based on ultrasonic technology has been preliminarily verified in the field of engineering, but there is still a lack of research on dynamic lubrication film thickness measurement. There is a blind area in the measurement of film thickness between the spring model and the resonance model based on ultrasonic technology. This is because the traditional model only uses the amplitude of reflection coefficient, leading to a certain blind area in the measurement range of the film thickness between the two models. In order to make full use of the information of the phase and amplitude of the reflection coefficient, a composite model is proposed to cover the blind area in the measurement. In order to realize the on-line monitoring of film thickness, a real-time ultrasonic measurement system of dynamic film thickness was built, and the influence of pair type and lubricant type on measuring blind area was studied. The theoretical model of ultrasonic measurement was established and the propagation law of ultrasonic wave in different friction pairs and different lubricants was simulated and analyzed. The results showed that the self-established measurement system could accurately track the film thickness with different periods and different waveforms. The film thickness with rectangular waveform had the best tracking accuracy, followed by sine waveform and triangle waveform, the sawtooth waveform had the worst tracking accuracy, and the tracking accuracy increased gradually with the increase of the period. It was found that one of the important sources of measurement error was the resolution of oscilloscope. Due to the resolution limitation, there was a gap between the actual measured resonance frequency and the ideal resonance frequency, so there was an error between the measured film thickness and the theoretical film thickness. The proposed composite model can measure a wide range of film thickness without blind area by a single probe. With the increase of the acoustic impedance of the lower friction pair and lubricant, the measuring blind area of film thickness decreased gradually. The larger the acoustic impedance of the lower friction pair was, the larger the reflection coefficient of the lubricant-lower friction pair interface was, the smaller the transmitted acoustic pressure was, and the reflected sound wave containing the film thickness information was enhanced. Therefore, the measurement blind area was inversely proportional to the acoustic impedance of the lower friction pair. The reflection coefficient of the upper friction pair-lubricant interface increases with the decrease of the acoustic impedance of the lubricant, that was, the energy of the reflected wave b1 increased, the energy of the transmitted wave entering the lubricant decreased, so the energy of the reflected wave b2 containing the film thickness information also decreased. Therefore, the measurement blind area increased with the decrease of the acoustic impedance of the lubricant, and the measurement range of the film thickness of the three models became smaller. When the spring model is used to measure large film thickness, the amplitude curves of reflection coefficient overlap each other and difficult to distinguish. When the acoustic impedance of the lubricant is too small, "unmeasurable vacuum zone" can easily occur. This paper provides theoretical and experimental data for on-line monitoring of lubrication film thickness of precision rotating parts under actual working conditions. © 2024 Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences. All rights reserved.
引用
收藏
页码:214 / 232
页数:18
相关论文
共 31 条
  • [11] Fan Zhang, Ouyang Wu, Honglun Hong, Et al., Experimental study on pad temperature and film thickness of tilting-pad journal bearings with an elastic-pivot pad[J], Tribology International, 88, pp. 228-235, (2015)
  • [12] McCarthy D M C, Glavatskih S B, Sherrington I., Oil-film thickness and temperature measurements in PTFE and Babbitt faced tilting-pad thrust bearings[J], Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 219, 3, pp. 179-185, (2005)
  • [13] Glavatskih S B, Uusitalo O, Spohn D J., Simultaneous monitoring of oil film thickness and temperature in fluid film bearings[J], Tribology International, 34, 12, pp. 853-857, (2001)
  • [14] Miranda G C., The detection of journal bearing cavitation with use of ultrasound technology, (2016)
  • [15] Dwyer-Joyce R S, Drinkwater B W, Donohoe C J., The measurement of lubricant-film thickness using ultrasound[J], Proceedings of the Royal Society of London Series A: Mathematical, Physical and Engineering Sciences, 459, 2032, pp. 957-976, (2003)
  • [16] Praher B, Steinbichler G., Ultrasound-based measurement of liquid-layer thickness: a novel time-domain approach[J], Mechanical Systems and Signal Processing, 82, pp. 166-177, (2017)
  • [17] Dou Pan, Wu Tonghai, Peng Zhongxiao, A time-domain ultrasonic approach for oil film thickness measurement with improved resolution and range, Measurement Science and Technology, 31, 7, (2020)
  • [18] Pialucha T, Cawley P., The detection of thin embedded layers using normal incidence ultrasound[J], Ultrasonics, 32, 6, pp. 431-440, (1994)
  • [19] Pialucha T, Guyott C C H, Cawley P., Amplitude spectrum method for the measurement of phase velocity[J], Ultrasonics, 27, 5, pp. 270-279, (1989)
  • [20] Dou Pan, Jia Yaping, Wu Tonghai, Et al., High-accuracy incident signal reconstruction for in situ ultrasonic measurement of oil film thickness, Mechanical Systems and Signal Processing, 156, (2021)