BioComm: Biocompatible Physical Layer Design for Wireless Intra-Body Communications

被引:0
|
作者
Johari, Pedram [1 ]
Elayan, Hadeel [1 ]
Jornet, Josep M. [1 ]
机构
[1] Northeastern Univ, Dept Elect & Comp Engn, Boston, MA 02115 USA
基金
美国国家科学基金会;
关键词
Nanobioscience; Terahertz communications; Biomedical optical imaging; Biological tissues; Nanoscale devices; Biological system modeling; Optical propagation; Intra-body wireless communications; biocompatible modulation; in-vivo wireless nanosensor networks; terahertz and optical communications; Internet of Nano Things (IoNT); SURFACE-PLASMON RESONANCE; NANOSENSOR NETWORKS; CHANNEL MODEL; TERAHERTZ; THRESHOLDS; ANTENNAS; TISSUES; DAMAGE;
D O I
10.1109/TMBMC.2024.3423021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In-vivo Wireless Nanosensor Networks (iWNSNs) consist of nano-sized communicating devices with unprecedented sensing capabilities that operate inside the human body in real-time. The current state-of-the-art in nanoelectronics and nanophotonics points to the Terahertz (THz) band (0.1-10 THz) and the optical frequency bands (infrared, 30-400 THz, and visible, 400-750 THz) as the promising spectral bands for nanosensor communications. In this paper, we propose and analyze a biocompatible modulation technique for iWNSNs. A mathematical framework is formulated to optimize the parameters of an adaptive Time Spread On-Off Keying (OOK) pulse-based modulation. This optimization considers both the physics of the intra-body optical channel and the light-matter interactions, along with the resulting photo-thermal effects in biological tissues. The outcomes of the analytical optimization model are validated through extensive numerical simulations. The results highlight a trade-off between link efficiency and the biocompatibility of the transmitted signals. Numerical analysis shows that the proposed biocompatible modulation technique can easily achieve a Bit Error Rate (BER) of $10<^>{-2}$ before coding, within the bio-safety measures, indicating a reliable intra-body channel for data transmission. This means that the channel can effectively convey information, such as health monitoring data or control signals for medical devices, without significant data loss or corruption.
引用
收藏
页码:383 / 395
页数:13
相关论文
共 50 条
  • [21] Investigation and Comparison of Two Models in Galvanic Coupling Intra-body Communications
    Pun Siohang
    Gao Yueming
    Wong Kuokkit
    Mak Pengun
    Vai Mangi
    Du Min
    CHINA COMMUNICATIONS, 2010, 7 (04) : 35 - 40
  • [22] Experimental Evaluation of Body Channel Response and Digital Modulation Schemes for Intra-body Communications
    Ruiz, Jordi Agud
    Shimamoto, Shigeru
    2006 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, VOLS 1-12, 2006, : 349 - 354
  • [23] Intra-Body Optical Channel Modeling for In Vivo Wireless Nanosensor Networks
    Guo, Hongzhi
    Johari, Pedram
    Miquel, Josep
    Sun, Zhi
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2016, 15 (01) : 41 - 52
  • [24] Wireless Intra-Body Power Transfer via Capacitively Coupled Link
    Mohammed, Noor
    Jackson, Robert W.
    Gummeson, Jeremy
    Lee, Sunghoon Ivan
    2022 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI'22) JOINTLY ORGANISED WITH THE IEEE-EMBS INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN'22), 2022,
  • [25] Embedded Nano Relay for Intra-Body Network-Based Molecular Communications
    Abd El-atty, Saied M.
    Bidar, Reda
    El-Rabaie, El-Sayed M.
    WIRELESS PERSONAL COMMUNICATIONS, 2022, 125 (04) : 3049 - 3066
  • [26] Quasi-Static Modeling of Human Limb for Intra-Body Communications With Experiments
    Pun, Sio Hang
    Gao, Yue Ming
    Mak, PengUn
    Vai, Mang I.
    Du, Min
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (06): : 870 - 876
  • [27] Intra-body communications for nervous system applications: Current technologies and future directions
    Vizziello, Anna
    Magarini, Maurizio
    Savazzi, Pietro
    Galluccio, Laura
    COMPUTER NETWORKS, 2023, 227
  • [28] Experimental Evaluation of Impulsive Ultrasonic Intra-Body Communications for Implantable Biomedical Devices
    Santagati, G. Enrico
    Melodia, Tommaso
    IEEE TRANSACTIONS ON MOBILE COMPUTING, 2017, 16 (02) : 367 - 380
  • [29] IBCFAP: Intra-Body Communications Five-Layers Arm Phantom Model
    Khorshid, Ahmed E.
    Alquaydheb, Ibrahim N.
    Eltawil, Ahmed M.
    Kurdahi, Fadi J.
    IEEE ACCESS, 2019, 7 (93701-93710): : 93701 - 93710
  • [30] Embedded Nano Relay for Intra-Body Network-Based Molecular Communications
    Saied M. Abd El-atty
    Reda Bidar
    El-Sayed M. El-Rabaie
    Wireless Personal Communications, 2022, 125 : 3049 - 3066