Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum

被引:0
|
作者
Huang, Kuan-Hsun [1 ]
Yu, Cheng-Xue [1 ]
Lee, Chia-Chun [2 ,3 ]
Tseng, Chin-Chung [2 ,3 ]
Fu, Lung-Ming [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Coll Med, Div Nephrol,Dept Internal Med, Tainan 704, Taiwan
[3] Natl Cheng Kung Univ, Inst Clin Med, Coll Med, Tainan 704, Taiwan
来源
BIOSENSORS-BASEL | 2025年 / 15卷 / 02期
关键词
sodium; microfluidic; finger pump; micro-spectrometer; chronic kidney disease; SENSOR;
D O I
10.3390/bios15020104
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic system for detecting sodium ions (Na+) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na+ concentration in human serum. A small volume (10 mu L) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na+ concentration is then inversely derived from the measured A555/A666 absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na+ concentration within the range of 1-200 mM, with a correlation coefficient of R2 = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R2 = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na+ detection methods, making it highly promising for point-of-care (POC) testing applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] RAPID, SIMULTANEOUS DETERMINATION OF PROTEIN AND SALT CONCENTRATIONS IN ION-EXCHANGE FRACTIONS
    SHAMBAUGH, GE
    MAKER, A
    RADOSEVICH, JA
    BIOTECHNIQUES, 1995, 19 (05) : 725 - &
  • [32] IMPROVEMENTS IN HEMOGLOBIN-AI DETERMINATION BY RAPID ION-EXCHANGE CHROMATOGRAPHY
    RAND, PG
    NELSON, C
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1048 - 1048
  • [33] A RAPID METHOD FOR THE DETERMINATION OF RADIONUCLIDES IN REACTOR COOLANT BY ION-EXCHANGE MEMBRANES
    CHAN, CC
    LIU, PC
    WENG, PS
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1985, 95 (02) : 81 - 92
  • [35] Evaluation of a "point-of-care" system for the determination of glycated hemoglobin
    Previtali, Giuseppe
    Amadei, Marina
    Donati, Mirella
    Frasanni, Michela
    Zurlini, Corrado
    BIOCHIMICA CLINICA, 2012, 36 (05) : 388 - 389
  • [37] USE OF ION-EXCHANGE RESINS FOR RAPID CONCENTRATION OF DILUTE-SOLUTIONS OF PROTEINS
    ZIMMERMAN, DH
    KNIGHT, GJ
    BOND, HE
    FEDERATION PROCEEDINGS, 1976, 35 (07) : 1382 - 1382
  • [38] DETERMINATION OF SERUM IONIZED CALCIUM BY ION-EXCHANGE ELECTRODE IN NORMAL SUBJECTS
    CONCEICAO, SC
    WARD, MK
    ALVAREZUDE, F
    ALJAMA, P
    SMITH, P
    KERR, DNS
    CLINICA CHIMICA ACTA, 1978, 86 (02) : 143 - 151
  • [39] RAPID FINGERSTICK BASED POINT-OF-CARE SYSTEM FOR IGE QUANTIFICATION
    Geng, B.
    Terpstra, C.
    Karlin, E.
    Harder, C.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2021, 127 (05) : S13 - S13
  • [40] Rapid Point-of-Care Test for Determination of C-Peptide Levels
    Rao, Paturi V.
    Bean, Eric
    Nair-Schaef, Dhanalakshmi
    Chen, Siting
    Kazmierczak, Steven C.
    Roberts, Charles T., Jr.
    Nagalla, Srinivasa R.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (04): : 976 - 981