High-resolution electron microscopy imaging of MOFs at optimized electron dose

被引:0
|
作者
Kavak, Safiyye [1 ]
Jannis, Daen [1 ]
De Backer, Annick [1 ]
Esteban, Daniel Arenas [1 ]
Annys, Arno [1 ]
Carrasco, Sergio [2 ]
Ferrando-Ferrero, Javier [2 ]
Guerrero, Raul M. [2 ]
Horcajada, Patricia [2 ]
Verbeeck, Jo [1 ]
Van Aert, Sandra [1 ]
Bals, Sara [1 ]
机构
[1] Univ Antwerp, Electron Microscopy Mat Sci EMAT, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[2] IMDEA Energy Inst, Adv Porous Mat Unit, Mostoles 28935, Madrid, Spain
基金
欧盟地平线“2020”;
关键词
METAL-ORGANIC FRAMEWORKS; PHASE-CONTRAST; NODE CONNECTIVITY; RADIATION-DAMAGE; GAS-STORAGE; CYCLOADDITION; CATALYSTS; STEM; CO2; EPOXIDES;
D O I
10.1039/d4ta06724j
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Local and high-resolution structural investigation of metal-organic frameworks (MOFs) is essential for understanding the role of defects and incorporated elements. In this paper, we characterize the structure of metalated versions of (Hf)PCN-222(H2) and locate the position of the additional metal atoms. Transmission electron microscopy (TEM) is a powerful technique for this purpose, but MOFs are highly sensitive to the electron beam. To avoid structural alterations, it is therefore crucial to establish the maximum electron dose that can be applied. In this study, we apply a systematic workflow to measure the critical electron dose, enabling the identification of the optimal technique for extracting reliable information about the local structure of MOFs. We examined the electron beam stability of benchmarked (Zr)NU-1000, (Hf)PCN-222(H2) and its metalated versions, (Hf)PCN-222(Fe) and (Hf)PCN-222(Pd), and identified factors influencing the stability under the electron beam. After the threshold for electron dose was established, we applied low-dose, four-dimensional scanning transmission electron microscopy (4D-STEM). We then compared annular bright field (ABF), annular dark field (ADF), and real-time integrated center of mass (riCOM) images that could be extracted from the 4D dataset. The riCOM technique successfully revealed the structure of investigated MOFs with minimal beam-induced alterations and provides insights into local features, including organic linkers and additional metalation elements.
引用
收藏
页码:4281 / 4291
页数:11
相关论文
共 50 条
  • [41] HIGH-RESOLUTION IMMUNOSCANNING ELECTRON-MICROSCOPY
    OGURA, K
    HASEGAWA, Y
    JOURNAL OF ELECTRON MICROSCOPY, 1990, 39 (03): : 212 - 212
  • [42] Quantitative high-resolution electron microscopy of interfaces
    Ernst, F
    Hofmann, D
    Nadarzinski, K
    Schmidt, C
    Stemmer, S
    Streiffer, SK
    INTERGRANULAR AND INTERPHASE BOUNDARIES IN MATERIALS, PT 1, 1996, 207 : 23 - 34
  • [43] WORKSHOP ON HIGH-RESOLUTION ELECTRON-MICROSCOPY
    THOMAS, G
    GLAESER, RM
    COWLEY, J
    SINCLAIR, R
    ULTRAMICROSCOPY, 1978, 3 (01) : 103 - 104
  • [44] HIGH-RESOLUTION ANALYTICAL ELECTRON-MICROSCOPY
    CARPENTER, RW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 102 - INOR
  • [45] SURVEY OF ELECTRON SOURCES FOR HIGH-RESOLUTION MICROSCOPY
    ORLOFF, J
    ULTRAMICROSCOPY, 1989, 28 (1-4) : 88 - 97
  • [46] WORKSHOP ON HIGH-RESOLUTION ELECTRON-MICROSCOPY
    不详
    MICRON, 1977, 8 (03) : 173 - 174
  • [47] HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY
    GIBSON, JM
    MRS BULLETIN, 1991, 16 (03) : 27 - 33
  • [48] HIGH-RESOLUTION TRANSMISSION ELECTRON-MICROSCOPY
    GRUEHN, R
    ROSS, R
    CHEMIE IN UNSERER ZEIT, 1987, 21 (06) : 194 - 206
  • [49] High-resolution electron microscopy of technegas and pertechnegas
    Isawa, T
    Lee, BT
    Hiraga, K
    NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (02) : 147 - 152
  • [50] HIGH-RESOLUTION ELECTRON-MICROSCOPY OF DUMORTIERITE
    VANDYCK, D
    TAMBUYSER, P
    VANLANDUYT, J
    AMELINCKX, S
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1976, 57 (08): : 603 - 603