Enhancing Fault Ride Through Capability of Grid-Forming Virtual Synchronous Generators Using Model Predictive Control

被引:3
|
作者
Pouresmaeil, Mobina [1 ]
Sangrody, Reza [2 ]
Taheri, Shamsodin [2 ]
Montesinos-Miracle, Daniel [3 ]
Pouresmaeil, Edris [1 ]
机构
[1] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[2] Univ Quebec Outaouais UQO, Dept Informat Sci & Technol, Gatineau, PQ J8X 3X7, Canada
[3] Univ Politecn Catalunya UPC, Ctr Innovacio Tecnol Convertidors Estat & Accionam, Barcelona 08028, Spain
关键词
Voltage control; Limiting; Power system stability; Circuit faults; Impedance; Predictive control; Synchronous generators; Fault ride-through (FRT); grid-forming converters; model predictive control (MPC); symmetrical/ asymmetrical faults; virtual resistance; virtual synchronous generator (VSG);
D O I
10.1109/JESTIE.2024.3355885
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes a control method for virtual synchronous generator-based grid-forming converters to improve the stability of power electronic-dominated power grids. Overcurrent protection and fault ride-through (FRT) are crucial for the control of converter-based generators, given the limitations of power electronics components. This article introduces a finite-set model predictive control (FS-MPC)-based FRT control technique that ensures system stability during symmetrical and asymmetrical fault types by incorporating overcurrent protection and contribution to the system voltage, while maintaining the voltage mode functionalities of the grid-forming converters. Compared to conventional control methods, the proposed MPC control technique allows for faster and improved dynamics, which makes control objectives more accessible. In addition, the approach coordinates voltage and current control and their limitations to ensure system stability during and after fault. The proposed method also adapts to different fault types and sizes without requiring fault type detection. Simulation results in MATLAB/Simulink illustrate the effectiveness of the proposed control method in limiting the current and ensuring high power quality by providing clean sinusoidal voltage and current waveforms. Hardware-in-the-loop real-time simulation is also presented to validate the controller performance under fault conditions.
引用
收藏
页码:1192 / 1203
页数:12
相关论文
共 50 条
  • [31] DC Voltage Control with Grid-Forming Capability for Enhancing Stability of HVDC System
    Shafique, Ghazala
    Boukhenfouf, Johan
    Gruson, Francois
    Colas, Frederic
    Guillaud, Xavier
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2025, 13 (01) : 66 - 78
  • [32] An Adaptive Fault Ride-Through Scheme for Grid-Forming Inverters Under Asymmetrical Grid Faults
    Li, Zilin
    Chan, Ka Wing
    Hu, Jiefeng
    Or, Siu Wing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (12) : 12912 - 12923
  • [33] A fault ride-through strategy for grid-forming converters under symmetrical and asymmetrical grid faults
    Zhao, Xianxian
    Kestelyn, Xavier
    Flynn, Damian
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 235
  • [34] Research on the control parameters of grid-forming based on virtual synchronous generator technology
    Zhu, Shengbo
    Gao, Qingzhong
    2024 3RD INTERNATIONAL CONFERENCE ON ENERGY AND ELECTRICAL POWER SYSTEMS, ICEEPS 2024, 2024, : 1406 - 1409
  • [35] Frequency Stability Analysis of Grid-Forming PMSG Based on Virtual Synchronous Control
    Meng, Qingtian
    Ren, Yongfeng
    Liu, Huiqiang
    IEEE ACCESS, 2024, 12 : 84134 - 84148
  • [36] Nonlinear Backstepping Control of Grid-Forming Converters in Presence of Grid-Following Converters and Synchronous Generators
    Karunaratne, Lilan
    Chaudhuri, Nilanjan Ray
    Yogarathnam, Amirthagunaraj
    Yue, Meng
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (01) : 1948 - 1964
  • [37] Enhancement of low-voltage ride-through capability for virtual synchronous generators based on virtual impedance voltage control
    Ji, Feng
    Xu, Zhuang
    ENERGY REPORTS, 2023, 9 : 406 - 415
  • [38] A Model Predictive Control With Grid-Forming Capability for Back-to-Back Converters in Wind Turbine Systems
    Zeng, Zhijie
    Chen, Dawei
    Qin, Shiyao
    Yuan, Shuai
    Zou, Zhixiang
    Chen, Jinyu
    Qi, Chen
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1697 - 1708
  • [39] A Novel Control Strategy for the Doubly Fed Induction Generators to Improve Grid Fault Ride-Through Capability
    Bu, S. Q.
    Du, W.
    Wang, H. F.
    Chen, Z.
    Xiao, L. Y.
    Li, H. F.
    2011 2ND IEEE PES INTERNATIONAL CONFERENCE AND EXHIBITION ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT EUROPE), 2011,
  • [40] Grid Inertia and Damping Support Enabled by Proposed Virtual Inductance Control for Grid-Forming Virtual Synchronous Generator
    Li, Chang
    Yang, Yaqian
    Cao, Yijia
    Aleshina, Alena
    Xu, Jiazhu
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (01) : 294 - 303