Pressure estimation of ultra-high frequency ultrasound using gas vesicles

被引:0
|
作者
Strohm, Eric M. [1 ,2 ,3 ]
Wu, Di [4 ]
Malounda, Dina [4 ]
Nayak, Rohit [4 ]
Shapiro, Mikhail G. [4 ,5 ,6 ]
Kolios, Michael C. [1 ,2 ,3 ]
机构
[1] Department of Physics, Toronto Metropolitan University, formerly Ryerson University, Toronto,ON,M5B 2K3, Canada
[2] Institute for Biomedical Engineering, Science and Technology, A Partnership Between Toronto Metropolitan University, St. Michael's Hospital, Toronto,ON,M5B 2K3, Canada
[3] Keenan Research Centre for Biomedical Science, St. Michael's Hospital, Toronto,ON,M5B 1T8, Canada
[4] Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena,CA,91125, United States
[5] Division of Engineering and Applied Science, California Institute of Technology, Pasadena,CA,91125, United States
[6] Howard Hughes Medical Institute, California Institute of Technology, Pasadena,CA,91125, United States
来源
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
Acoustic microscopes - Frequency estimation - Pressure transducers - UHF devices - Ultrasonic imaging - Ultrasonic sensors - Ultrasonic transducers - Ultrasonics;
D O I
10.1121/10.0034438
中图分类号
学科分类号
摘要
Acoustic microscopy uses ultra-high frequency (UHF) ultrasound transducers over 80 MHz to perform high-resolution imaging. The pressure output of these transducers is unknown, as commercial calibrated hydrophones can measure pressure for transducers with frequencies only up to 80 MHz. This study used gas vesicle nanostructures (GVs) that collapse at 571 kPa to estimate the pressure of UHF transducers at 40, 80, 200, and 375 MHz. Agarose phantoms containing GVs were made, and a baseline ultrasound image was performed at low pressure to prevent GV collapse. Sections within the phantom were scanned at varying voltage to determine the GV collapse threshold. The pressure at full driving voltage was then calculated, assuming a linear relation between transducer voltage and pressure. The pressure calculated for the 40 MHz transducer was 2.2 ± 0.1 MPa at 21 °C. Using a hydrophone, the measured pressure was 2.1 ± 0.3 MPa, a difference of © 2024 Acoustical Society of America.
引用
收藏
页码:4193 / 4201
相关论文
共 50 条
  • [21] Clinical application of ultra-high frequency ultrasound: Discovering a new imaging frontier
    Fogante, Marco
    Carboni, Nicola
    Argalia, Giulio
    JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (06) : 817 - 825
  • [22] Ultra-high frequency ultrasound in planning capillary perforator flaps: Preliminary experience
    Visconti, Giuseppe
    Hayashi, Akitatsu
    Yoshimatsu, Hidehiko
    Bianchi, Alessandro
    Salgarello, Marzia
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (08): : 1148 - 1149
  • [23] Investigation of Ultra-High Pressure Gas Control System for Hydrogen Vehicles
    Kim, Roh-Won
    Hwang, Kyung-Hwan
    Kim, Sung-Ryul
    Lee, Jae-Hak
    ENERGIES, 2020, 13 (10)
  • [24] The use of ultra-high frequency ultrasound in identifying aganglionosis in Hirschsprung’s disease
    Tebin Hawez
    Maria Evertsson
    Tobias Erlöv
    Kristine Hagelsteen
    Louise Tofft
    Tomas Jansson
    Magnus Cinthio
    Christina Granéli
    Pernilla Stenström
    Scientific Reports, 15 (1)
  • [25] ULTRA-HIGH FREQUENCY DRIFT WAVES
    DETYNA, E
    WOODING, ER
    PLASMA PHYSICS, 1972, 14 (02): : 97 - &
  • [26] ULTRA-HIGH FREQUENCY DENATURATION OF PROTEINS
    BOYD, GA
    JOURNAL OF CHEMICAL PHYSICS, 1946, 14 (05): : 351 - 352
  • [27] ULTRA-HIGH FREQUENCY BEAM ANALYZER
    BLOOM, LR
    VONFOERSTER, HM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (07): : 649 - 653
  • [28] TRIODES AND KLYSTRONS AT ULTRA-HIGH FREQUENCY
    LUNDSTROM, OC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1965, NS12 (03) : 222 - +
  • [29] ULTRA-HIGH PRESSURE VESSEL DESIGN
    MANNING, WRD
    CHEMICAL AND PROCESS ENGINEERING, 1967, 48 (03): : 51 - &
  • [30] TRANSFORMATION IN BERYLLIUM AT ULTRA-HIGH PRESSURE
    MARDER, AR
    JOM-JOURNAL OF METALS, 1964, 16 (01): : 120 - &