Real-time optical detection of mercury contamination in drinking water using an amphiphilic recognition probe at liquid crystal/aqueous interfaces

被引:0
|
作者
Pandey, Satyabratt [1 ]
Rashid, Madeeha [1 ]
Singh, Vishal [1 ]
Singh, Garima [1 ]
Patel, Chandan Bhai [2 ]
Verma, Rohit [3 ]
Dev, Dharm [4 ]
Singh, Ranjan Kumar [2 ]
Singh, Sachin Kumar [1 ]
机构
[1] Deen Dayal Upadhyay Gorakhpur Univ, Dept Chem, Gorakhpur 273009, India
[2] BHU, Dept Phys, Inst Sci, Varanasi 221005, India
[3] Amity Univ, Amity Inst Appl Sci, Dept Phys, Noida, India
[4] GSVM Med Coll, Dept Pharmacol, Kanpur 208002, India
关键词
CRYSTAL BASED SENSOR; TURN-ON PROBE; AQUEOUS-MEDIUM; IONS; SYSTEM; LIGAND; HG2+; DNA;
D O I
10.1039/d4ay01482k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mercury contamination is a global environmental issue due to its toxicity and persistence in ecosystems. It poses a particular risk in aquatic systems, where it bioaccumulates and biomagnifies, leading to serious health impacts on humans. Therefore, effective detection technologies for mercuric ions in natural water resources are highly desirable. However, most existing detection methods are time-consuming, require complicated sample pre-treatment, and rely on expensive equipment, which hinders their widespread use in real-time detection. Here, we present a convenient, rapid, portable, user-friendly, and cost-effective sensing system for detecting Hg2+ ion contamination in water. This system utilizes a highly selective, amphiphilic, and structurally simple molecular probe, N-dodecylamine-di-thiocarbamate (DDC). DDC molecules align at the interface between the liquid crystal (LC) and water, inducing a homeotropic LC orientation. In water samples contaminated with Hg2+, a bright optical texture is observed, indicating the alignment of the 5CB LC in a planar manner at the LC/aqueous boundary. The minimum detectable concentration (LOD) for Hg2+ ions is 5.0 mu M in distilled water, with a broad detection range from 5.0 mu M to 2 mM. The sensor selectively detects Hg2+ ions over other common interfering metal ions, including Pb2+, Co2+, Ni2+, Cu2+, Cd2+, Zn2+, Cr2+, Mg2+, Na+, K+, and Ca2+. Boolean logic gates, bar graphs, and truth tables are employed to explain the selectivity of this liquid crystal-based sensor. This work demonstrates the significant potential of the sensor for monitoring mercuric ions in natural water resources, offering a promising strategy for controlling mercury pollution.
引用
收藏
页码:8139 / 8147
页数:10
相关论文
共 50 条
  • [41] Real-time aqueous tritium monitor using liquid scintillation counting
    Nucl Instrum Methods Phys Res Sect A, 1-3 (494):
  • [42] Cheap and reconfigurable PC-board for real-time optical applications using liquid crystal displays
    PerezPoch, A
    Velasco, J
    Carrabina, J
    Millan, MS
    DESIGN AND ENGINEERING OF OPTICAL SYSTEMS, 1996, 2774 : 757 - 765
  • [43] REAL-TIME OPTICAL-INTENSITY CORRELATOR USING PHOTOREFRACTIVE BSO AND A LIQUID-CRYSTAL TELEVISION
    SOUTAR, C
    WANG, ZQ
    CARTWRIGHT, CM
    GILLESPIE, WA
    JOURNAL OF MODERN OPTICS, 1992, 39 (04) : 761 - 769
  • [44] High-sensitive liquid crystal-based optical sensor for real-time detection of formaldehyde vapor
    Chen, Zhongyu
    Fu, Shaohai
    Guan, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 431
  • [45] Optical-microwave sensor for real-time measurement of water contamination in oil derivatives
    Abdulsattar, Rusul Khalid
    Alibakhshikenari, Mohammad
    Virdee, Bal S.
    Sharma, Richa
    Elwi, Taha A.
    Kouhalvandi, Lida
    Hassain, Zaid A. Abdul
    Ali, Syed Mansoor
    Tokan, Nurhan Turker
    Livreri, Patrizia
    Falcone, Francisco
    Limiti, Ernesto
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2023, 170
  • [46] Using Multidimensional ADTPE and SVM for Optical Modulation Real-Time Recognition
    Wei, Junyu
    Huang, Zhiping
    Su, Shaojing
    Zuo, Zhen
    ENTROPY, 2016, 18 (01)
  • [47] Real-time pattern recognition using an optical generalized Hough transform
    Fernandez, Ariel
    Flores, Jorge L.
    Alonso, Julia R.
    Ferrari, Jose A.
    APPLIED OPTICS, 2015, 54 (36) : 10586 - 10591
  • [48] REAL-TIME NONCOHERENT CORRELATOR USING LIQUID-CRYSTAL TELEVISION
    JUTAMULIA, S
    LIN, TW
    YU, FTS
    OPTICS COMMUNICATIONS, 1987, 64 (02) : 115 - 119
  • [49] REAL-TIME NONCOHERENT CORRELATION USING LIQUID CRYSTAL TELEVISION.
    Jutamulia, S.
    Lin, T.W.
    Yu, F.T.S.
    Optics Communications, 1987, 64 (02): : 115 - 119
  • [50] ON REAL-TIME HOLOGRAPHY USING A LIQUID CRYSTAL DISPLAY DEVICE.
    Fujiki, Shigeo
    Hakoyama, Akiyoshi
    Suzuki, Michio
    Electronics and Communications in Japan (English translation of Denshi Tsushin Gakkai Zasshi), 1974, 57 (02): : 106 - 112