Analysis, Modeling, and Experiments of a Nonlinear Inductor-Based Fault Current Commutation Strategy for a Hybrid DC Circuit Breaker

被引:0
|
作者
Yang, Qichen [1 ]
Steurer, Michael [1 ]
Song, Sihun [1 ]
Pickles, Matthew [1 ]
He, Yuchen [2 ]
Hauer, John Daniel [1 ]
Bosworth, Matthew [1 ]
Bonaventura, Nash [1 ]
Coleman, Michael [1 ]
Shi, Yanjun [3 ]
Kim, Sanghun [4 ]
Gonzatti, Robson Bauwelz [5 ]
Schoder, Karl [1 ]
Graber, Lukas [6 ]
Li, Yuan [1 ]
Peng, Fang Z. [1 ]
机构
[1] Florida State Univ, Ctr Adv Power Syst, Tallahassee, FL 32310 USA
[2] Lucid Grp Inc, Newark, CA 94560 USA
[3] Tesla Inc, Palo Alto 94304, CA USA
[4] Korea Inst Energy Res, Daejeon 34141, South Korea
[5] Itajuba Fed Univ UNIFEI, BR-37500903 Itajuba, Brazil
[6] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
Frequency modulation; Inductors; Inductance; Magnetic cores; Fault currents; Voltage; Circuit breakers; DC circuit breaker (dcCB); hybrid breaker; medium-voltage; modeling; nonlinear inductor; optimized design; LOSSES;
D O I
10.1109/TTE.2024.3435928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Mediumvoltage dc (MVdc) power system offers a potent solution for high power density, agility, and robustness required by electric ships with escalating power needs. However, the dc power systems suffer from short-circuit fault managing issues. To solve the issue, a hybrid dc circuit breaker (dcCB) has been developed, featuring a novel piezoelectric actuated fast mechanical switch (FMS) and a sequential metal-oxide varistor (MOV) insertion scheme. A key innovation is its nonlinear inductor-based fault current commutation strategy, designed for fast fault current extinguishment and ensuring arc-less operation of the FMS. Using the saturation phenomenon properly, the inductor with variable inductance can hold current around zero to enable arc-less opening of the FMS without slowing down the fault current commutation speed. The article analyzes the features of the nonlinear inductor and presents a fractal RL circuit to model the frequency-related inductance variance and the saturation phenomenon in the time domain. Based on the model of the circuit breaker, including the nonlinear inductor, a genetic algorithm (GA)-based multiobjective optimization method is developed to design the fault current commutation circuit (FC3). Experimental results with 4-kV dc voltage are presented to confirm the accuracy of the model of the nonlinear inductor and the optimized design method.
引用
收藏
页码:7894 / 7906
页数:13
相关论文
共 50 条
  • [31] Analysis and Experiments for IGBT, IEGT, and IGCT in Hybrid DC Circuit Breaker
    Chen, Zhengyu
    Yu, Zhanqing
    Zhang, Xiangyu
    Wei, Tianyu
    Lyu, Gang
    Qu, Lu
    Huang, Yulong
    Zeng, Rong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (04) : 2883 - 2892
  • [32] Topology, Modeling and Transient Current Transfer Analysis of DC Hybrid Vacuum Circuit Breaker Based on SiC Module
    Wentao Jiang
    Xiaoming Liu
    Hai Chen
    Peiyuan Li
    Yaqian Zhang
    Journal of Electrical Engineering & Technology, 2021, 16 : 2809 - 2816
  • [33] Railway DC Circuit Breaker based on the Superconducting Fault Current Limiter
    Liu, Siyuan
    Yang, Kun
    Yang, Yi
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [34] Topology, Modeling and Transient Current Transfer Analysis of DC Hybrid Vacuum Circuit Breaker Based on SiC Module
    Jiang, Wentao
    Liu, Xiaoming
    Chen, Hai
    Li, Peiyuan
    Zhang, Yaqian
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (05) : 2809 - 2816
  • [35] A Hybrid DC Circuit Breaker for DC Microgrid Based on Zero Current Switching
    Keshavarzi, Davood
    Farjah, Ebrahim
    Ghanbarih, Teymoor
    2016 4TH IRANIAN CONFERENCE ON RENEWABLE ENERGY & DISTRIBUTED GENERATION (ICREDG), 2016, : 45 - 49
  • [36] Bidirectional Coupled Inductor Based Hybrid Circuit Breaker Topologies for DC System Protection
    Ray, Anindya
    Rajashekara, Kaushik
    Banavath, Satish Naik
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 1138 - 1145
  • [37] Nonlinear Inductor-Based Single Sensor Current Balancing Method for Interleaved DC-DC Converters
    Yao, Zhigang
    Lan, Haogang
    He, Xinyu
    Deng, Fei
    Wang, Caisheng
    Lu, Shuai
    Tang, Yi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (04) : 3996 - 4000
  • [38] Investigation of an Active Current Injection DC Circuit Breaker Based on a Magnetic Induction Current Commutation Module
    Wu, Yi
    Hu, Yang
    Wu, Yifei
    Rong, Mingzhe
    Yi, Qiang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1809 - 1817
  • [39] Study on Molten Bridge Behaviors with Arc-less Current Commutation in a Hybrid DC Circuit Breaker
    Chen, Mo
    Yamada, Yuta
    Zen, Shungo
    Yasuoka, Koichi
    2017 63RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2017, : 34 - 39
  • [40] Multi-port Commutation-based Hybrid DC Circuit Breaker with Low Conduction Loss Considering Bus Fault
    Shi W.
    Chen Y.
    Sun C.
    Wang W.
    Xie Y.
    Fang T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (14): : 140 - 149