METHYL IODIDE RETENTION ON CHARCOAL SORBENTS AT PARTS-PER-MILLION CONCENTRATIONS.

被引:0
|
作者
Wood, G.O.
Vogt, G.J.
Kasunic, C.A.
机构
来源
| 1978年
关键词
RADIOACTIVE MATERIALS - Filtration;
D O I
暂无
中图分类号
学科分类号
摘要
Breakthrough curves for charcoal beds challenged by air containing parts-per-million methyl iodide vapor concentrations were obtained and analyzed. A goal of this research is to determine if sorbent tests at relatively high vapor concentrations give data that can be extrapolated many orders of magnitude to the region of interest for radioiodine retention and removal. Another objective is to identify and characterize parameters that are critical to the performance of a charcoal bed in a respirator cartridge application. Towards these ends, a sorbent test system was built that allows experimental variations of the parameters of challenge vapor concentration, volumetric flow rate, bed depth, bed diameter, and relative humidity. Methyl iodide breakthrough was measured at a limit of 0. 002 ppm using a gas chromatograph equipped with a linearized electron capture detector. Effects of challenge concentration, relative humidity, and bed diameter were also investigated. Significant challenge concentration dependence was measured (more efficiency at lower concentration) for two types of charcoals. Increased relative humidity greatly decreased breakthrough times for a given protection factor. Increased bed diameter greatly increased breakthrough times for a given protection factor. Implications of these effects for a test method are discussed.
引用
收藏
相关论文
共 50 条
  • [21] A SIMPLE PROCEDURE TO CONVERT PARTS-PER-MILLION (PPM) TO MOLARITY (M)
    SUNBERG, RJ
    JOURNAL OF CHEMICAL EDUCATION, 1986, 63 (08) : 714 - 714
  • [22] A SIMPLE PROCEDURE TO CONVERT PARTS-PER-MILLION (PPM) TO MOLARITY (M)
    SUNBERG, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 1 - ACSC
  • [23] PARTS-PER-MILLION ACCURACY INSTRUMENT FOR AC VOLTAGE MEASUREMENTS.
    Arseneau, Rejean
    Zelle, John J.
    IEEE Transactions on Instrumentation and Measurement, 1986, IM-36 (02) : 330 - 332
  • [24] Parts-per-million level loading organocatalysed enantioselective silylation of alcohols
    Sang Yeon Park
    Ji-Woong Lee
    Choong Eui Song
    Nature Communications, 6
  • [25] A parts-per-million scale electrolyte additive for durable aqueous zinc batteries
    Shixun Wang
    Shengnan Wang
    Zhiquan Wei
    Yiqiao Wang
    Dechao Zhang
    Ze Chen
    Chunyi Zhi
    Nature Communications, 16 (1)
  • [26] Photoacoustic absorption spectrometer for highly transparent dielectrics with parts-per-million sensitivity
    Waasem, Niklas
    Fieberg, Stephan
    Hauser, Janosch
    Gomes, Gregory
    Haertle, Daniel
    Kuehnemann, Frank
    Buse, Karsten
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (02):
  • [27] The linear polarization of Southern bright stars measured at the parts-per-million level
    Cotton, Daniel V.
    Bailey, Jeremy
    Kedziora-Chudczer, Lucyna
    Bott, Kimberly
    Lucas, P. W.
    Hough, J. H.
    Marshall, Jonathan P.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2016, 455 (02) : 1607 - 1628
  • [28] DETERMINATION OF NITROGEN AND HYDROGEN AT PARTS-PER-MILLION LEVELS IN MILLIGRAM STEEL SAMPLES
    HARGROVE, GL
    SHEPARD, RC
    FARRAR, H
    ANALYTICAL CHEMISTRY, 1971, 43 (03) : 439 - &
  • [29] RATE AND MECHANISM OF AIR OXIDATION OF PARTS-PER-MILLION CONCENTRATIONS OF NITRIC-OXIDE IN PRESENCE OF WATER-VAPOR
    ENGLAND, C
    CORCORAN, WH
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1975, 14 (01): : 55 - 63
  • [30] Sponge halogenated natural products found at parts-per-million levels in marine mammals
    Vetter, W
    Stoll, E
    Garson, MJ
    Fahey, SJ
    Gaus, C
    Müller, JF
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2002, 21 (10) : 2014 - 2019