IMPROVING THE ACCURACY OF AMPLITUDE MEASUREMENTS BY SAMPLING OSCILLOSCOPES.

被引:0
|
作者
Levitas, B.N.
Roizentok, V.S.
Rossoskii, Ya.M.
Shapiro, E.I.
机构
关键词
COMPUTERS; MICROCOMPUTER; -; OSCILLOSCOPES; CATHODE RAY;
D O I
暂无
中图分类号
学科分类号
摘要
The authors discuss problems associated with the improvement of the accuracy of measurement of parameters of pulse and harmonic signals by the histogram method and with the measurement of high-frequency (HF) signal amplitude with the aid of a synchronizer. The following conclusions can be drawn from this study. The error in measuring signal parameters with the aid of a sampling oscilloscope depends on the noise in horizontal and vertical deflection channels. Application of the histogram method gives simple algorithms for measuring certain parameters of pulse and sinusoidal signals and makes it possible to eliminate the effect of the horizontal channel noise on the results of measurement. Vertical deflection channel noise is a source of a systematic error in the measurement of sinusoidal signal amplitude by the histogram method. This error can be calculated and eliminated as proved by experimental measurements carried out with the S9-9 precision sampling oscilloscope.
引用
收藏
页码:127 / 131
相关论文
共 50 条
  • [21] SAMPLING OSCILLOSCOPES AND SAMPLING ADAPTORS
    CALLICK, EB
    LAWSON, A
    WIRELESS WORLD, 1971, 77 (1431): : 449 - &
  • [23] Power Measurements for Compute Nodes: Improving Sampling Rates, Granularity and Accuracy
    Ilsche, Thomas
    Hackenberg, Daniel
    Graul, Stefan
    Schoene, Robert
    Schuchart, Joseph
    2015 SIXTH INTERNATIONAL GREEN COMPUTING CONFERENCE AND SUSTAINABLE COMPUTING CONFERENCE (IGSC), 2015,
  • [24] RANDOM SAMPLING WITH OSCILLOSCOPES
    LIPINSKI, K
    INTERNATIONALE ELEKTRONISCHE RUNDSCHAU, 1972, 26 (09): : 209 - &
  • [25] SAMPLING OSCILLOSCOPES AND DIGITAL STORAGE OSCILLOSCOPES - WHATS IN A NAME
    TILDEN, M
    ELECTRONIC PRODUCTS MAGAZINE, 1989, 32 (03): : 33 - 35
  • [26] CALIBRATION OF FAST SAMPLING OSCILLOSCOPES
    HENDERSON, D
    RODDIE, AG
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (08) : 673 - 679
  • [27] Eye diagrams and sampling oscilloscopes
    不详
    HEWLETT-PACKARD JOURNAL, 1996, 47 (06): : 8 - 9
  • [28] Improving the accuracy of temperature measurements
    Tong, Alan
    Sensor Review, 2001, 21 (03) : 193 - 198
  • [29] IMPROVING THE ACCURACY OF SINUSOIDAL SIGNAL AMPLITUDE METERS
    BITUS, AV
    BRODOVOI, VA
    CHERNYAVKA, AM
    MEASUREMENT TECHNIQUES USSR, 1988, 31 (10): : 997 - 999
  • [30] Effects of sampling rate and ADC width on the accuracy of amplitude and phase measurements in power-quality monitoring
    Kuhlmann, Volker
    Sinton, Alastair
    Dewe, Mike
    Arnold, Chris
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (02) : 758 - 764