HIGH-TIME-RESOLUTION LASER SPECTROMETER.

被引:0
|
作者
Kiryunikov, K.V.
Kochubei, S.A.
Chapovskii, P.L.
Lisitsyn, V.N.
机构
来源
Soviet journal of quantum electronics | 1980年 / 10卷 / 04期
关键词
D O I
10.1070/QE1980v010n04ABEH010124
中图分类号
TB51 [声学仪器]; TH74 [光学仪器];
学科分类号
0803 ; 0804 ;
摘要
A pulsed layer spectrometer was developed using a tunable He-Ar high-pressure laser. The accuracy of synchronizing the laser with an object being investigated was about 1 nsec. In order to automate the measurements, pulse voltmeters having a wide dynamic range and devices for analog processing of the signals were developed. The spectrometer was used to study the characteristics of the 2p//1//0-1s//5 transition in argon, in a nanosecond electric-discharge plasma. Measurements were made of the time dependence of the gain at the center of the transition and of the collisional broadening due to the helium (19 GHz/atm).
引用
收藏
页码:498 / 500
相关论文
共 50 条
  • [41] A High-Time-Resolution Time-to-Digital Converter Using Coupled Ring Oscillator with Phase Averaging
    Ogata, Daiki
    Kamiya, Ryosuke
    Toyoshima, Yusuke
    Ohhata, Kenichi
    2022 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS, APCCAS, 2022, : 195 - 198
  • [42] Early oriented isothermal crystallization of polyethylene studied by high-time-resolution SAXS/WAXS
    Stribeck, N.
    Camarillo, A. Almendarez
    Noechel, U.
    Boesecke, P.
    Bayer, R. K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) : 649 - 661
  • [43] OPTOISOLATOR FOR AUGER SPECTROMETER.
    Troshkin, V.A.
    Bernatskii, D.P.
    Instruments and experimental techniques New York, 1987, 30 (5 Pt 1): : 1139 - 1140
  • [44] SPECULAR INFRARED SPECTROMETER.
    Chernin, S.M.
    Soviet Journal of Optical Technology (English translation of Optiko-Mekhanicheskaya Promyshlennost), 1974, 41 (08): : 445 - 446
  • [45] A HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER WITH LASER DESORPTION AND A LASER IONIZATION SOURCE
    BOESL, U
    GROTEMEYER, J
    WALTER, K
    SCHLAG, EW
    ANALYTICAL INSTRUMENTATION, 1987, 16 (01): : 151 - 171
  • [46] CALIBRATION PROCEDURE FOR A FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER.
    Holmqvist, B.
    Johansson, P.I.
    Wiedling, T.
    Nuclear instruments and methods in physics research, 1985, A234 (03): : 488 - 494
  • [47] Label-Free, High-Time-Resolution, Single-Molecule Studies of Riboswitch Folding
    Daly, Nathan S.
    Hon, Jason J.
    Warren, Steven B.
    Trocchia, Scott M.
    Nuckolls, Colin
    Shepard, Kenneth L.
    Gonzalez, Ruben L., Jr.
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 363A - 363A
  • [48] Optical fiber ring resonator as a high-resolution spectrometer. Characterization and applications with single line diode lasers
    Presti, Damian
    Videla, Fabian A.
    Torchia, Gustavo A.
    OPTICAL ENGINEERING, 2018, 57 (05)
  • [49] CHARGE/MASS PARTICLE SPECTROMETER.
    Anon
    IBM technical disclosure bulletin, 1986, 29 (02): : 650 - 651
  • [50] Cluster observations of the substructure of a flux transfer event: analysis of high-time-resolution particle data
    Varsani, A.
    Owen, C. J.
    Fazakerley, A. N.
    Forsyth, C.
    Walsh, A. P.
    Andre, M.
    Dandouras, I.
    Carr, C. M.
    ANNALES GEOPHYSICAE, 2014, 32 (09) : 1093 - 1117