Gas evolving materials for improved low current interruption in high voltage current limiting fuses

被引:0
|
作者
Westinghouse Technology and Quality, Cent, Pittsburgh, United States [1 ]
机构
来源
IEEE Trans Power Delivery | / 1卷 / 258-265期
关键词
Electric arcs - Electric cables - Electric current control - Electric currents - Electric fuses - Systems analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Various organic and inorganic compounds have been identified to be very effective arc interrupters when applied to the silver elements of high power current limiting fuses (typical ratings for a single barrel range from 5.5 - 15.5 kV, 20 - 250 Amps). These compounds reduced the non-interruption band which occurs between the rated fuse current and the minimum interruption current. The lower current limit at which the fuse can interrupt is directly affected by the gases evolved during arcing. These new compounds generate gases and free radicals which assist in deionizing the arc by a combination of the gas species evolved, increased local pressure, and by not forming any carbon residues. These novel compounds and binders significantly improved the interruption capability of high power fuses at low current levels. Compounds, test methods, evaluation, actual short circuit tests in a high power lab, and theoretical analysis are described.
引用
收藏
相关论文
共 50 条
  • [21] A high voltage vacuum type hybrid current limiting fuses for double protection of the shunt power capacitors
    Hei, Hao
    Wan, Jimei
    ICEFA 2007: EIGHTH INTERNATIONAL CONFERENCE ON ELECTRIC FUSES AND THEIR APPLICATIONS, PROCEEDINGS, 2007, : 43 - 46
  • [22] An introduction to the IEEE guide for current limiting fuses
    Muench, FJ
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1200 - 1202
  • [23] Current limiting fuses: Application considerations and cautions
    Muench, F
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1238 - 1240
  • [24] Interruption of Direct Current at High-Voltage.
    Allaart, A.J.
    Elektrotechniek, 1985, 63 (09): : 905 - 919
  • [25] Current limiting fuses: Application considerations and cautions
    Muench, F
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1209 - 1211
  • [26] Application of current limiting fuses in distribution systems for improved power quality and protection
    Kojovic, L
    Hassler, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (02) : 791 - 800
  • [27] An introduction to the IEEE guide for current limiting fuses
    Muench, FJ
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1229 - 1231
  • [28] CURRENT LIMITING FUSES - A COMPARATIVE-EVALUATION
    WESTROM, AC
    CROOKS, WR
    NARANCIC, V
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 1870 - 1877
  • [29] SELECTING AND APPLYING CURRENT LIMITING FUSES.
    Bryda, T.J.
    Jones, Larry
    Wise, Jerry L.
    Plant Engineering (Barrington, Illinois), 1985, 39 (15): : 43 - 45
  • [30] PROPER APPLICATION OF CURRENT-LIMITING FUSES
    SCHAFFER, S
    EC&M-ELECTRICAL CONSTRUCTION AND MAINTENANCE, 1983, 82 (08): : 51 - 56