SUPPLYING FIXED AND STROBOSCOPIC LIGHT BEACONS FROM THE OVERHEAD GROUND WIRE ON 735 kv TRANSMISSION LINES.

被引:0
|
作者
Blais, R.
Berthiaume, R.
机构
来源
| 1979年
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 37 条
  • [21] Induced Voltage of Overhead Ground Wires in 50 0-kV Single-Circuit Transmission Lines
    Wang, Jianguo
    Wang, Yu
    Peng, Xiangyang
    Li, Xianqiang
    Xu, Xiaogang
    Mao, Xianyin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (03) : 1054 - 1062
  • [22] Practical Implementation of Monitoring and Ice Melting on 110 – 120 kV Overhead Transmission Lines Based on the Dip Angle of the Wire
    Fedotov A.I.
    Basyrov R.S.
    Abdullazyanov R.É.
    Vagapov G.V.
    Power Technology and Engineering, 2019, 53 (04) : 508 - 515
  • [23] Overhead lines insulation distance reduction due to stay wire's expansion from ground fires
    Psarros, E. G.
    Kontokostas, Ch. K.
    Tsarabaris, P. T.
    Karagiannopoulos, C. G.
    Bourkas, P. D.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2009, 3 (03) : 237 - 241
  • [24] Capacitive Power Tapping From Insulated Shield Wire of Overhead High Voltage Transmission Lines With Tuning
    Shu, Shengwen
    Zheng, Yuesheng
    Xia, Kai
    Qi, Guowei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 191 - 204
  • [26] Analysis of equivalent circuit for tapping electromagnetic power from overhead ground wires of typical transmission lines
    State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing
    400030, China
    不详
    Sichuan Province
    600072, China
    Dianwang Jishu, 7 (2052-2057):
  • [27] NEW FAULT LOCATION SYSTEM FOR POWER TRANSMISSION-LINES USING COMPOSITE FIBER-OPTIC OVERHEAD GROUND WIRE (OPGW)
    URASAWA, K
    KANEMARU, K
    TOYOTA, S
    SUGIYAMA, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (04) : 2005 - 2011
  • [28] "Virtual" Power Line Method to Correct the Calculation of Current Ground Faults in the Parallel Overhead Transmission Lines 110-220 kV
    Ukraintsev, A., V
    Nagay, I., V
    2016 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2016,
  • [29] An Approach for Estimating the Ground Current in Substations Where the Overhead Guard Wire of Transmission Lines are Connected to the Grounding Grid: Model, Validation, and Practical Application
    Tello, Marcos
    Tello, Victor B.
    Pulz, Lucas T. C.
    Ferraz, Renato G.
    Vidor, Fabio F.
    Gazzana, Daniel S.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (04) : 5533 - 5541
  • [30] Influence of Ground Wire Protection Angle on Upward Leader from 110-1000 kV AC Lines
    Wang, Xi
    He, Jinliang
    Yu, Zhanqing
    Zeng, Rong
    Shen, Xiaoli
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1128 - 1133