RESPONSE AND SELECTIVITY IN LARGE TURBO-GENERATOR EXCITATION LOSS DETECTION.

被引:0
|
作者
Chernovets, A.K.
Merkur'ev, G.V.
Solonenkin, A.A.
Goldmann, D.
机构
来源
Electric Technology, USSR | 1980年 / 04期
关键词
D O I
暂无
中图分类号
TM3 [电机];
学科分类号
080801 ;
摘要
Analyses the response and selectivity of devices used to detect turbo-generator out-of-step conditions by a mathematical model of the turbo-generator and power system elements. Although detection time can be important for highly utilized turbo-generators, detuning from synchronous overswing and asynchronous rotation is determinative. Detection by generator impedance or excitation current with monitoring of the stator voltage is therefore favored, although faster response is considered to be urgently required.
引用
收藏
页码:48 / 63
相关论文
共 50 条
  • [41] Digital mechanism modeling and vibration characteristic analysis for stator end winding of large turbo-generator
    Wang T.
    Wang H.
    Zhao Y.
    Li X.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (07): : 143 - 153
  • [42] End-winding vibration monitoring: Pivotal in preventing major damage on a large turbo-generator
    Tetreault, Andre
    Zhou Zhengping
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 1 - 6
  • [43] A theoretical investigation on the vibrational characteristics and torsional dynamic response of circumferentially cracked turbo-generator shafts
    Vaziri, A.
    Nayeb-Hashemi, H.
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2006, 43 (14-15) : 4063 - 4081
  • [44] An increment transfer matrix method for the torsional vibration response of steam turbo-generator shaft system
    He Chengbing
    Xing Cheng
    Shen Jian
    MECHANICAL ENGINEERING AND GREEN MANUFACTURING, PTS 1 AND 2, 2010, : 1082 - +
  • [45] Influences of Turbo-generator End Winding Dimensions on Electromagnetic Loss in the End Core and Metal Parts.
    Wang, L.
    Li, J.
    Li, W.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [46] Study on dynamic response of torsional vibration of turbo-generator unit caused by short circuit fault
    He, Chengbing
    Chen, Dongchao
    Gu, Yujiong
    MACHINE DESIGN AND MANUFACTURING ENGINEERING, 2012, 566 : 248 - 252
  • [47] Numerical Studies on the Flow Field of Stator and Air Gap for Large Air-cooled Turbo-generator
    Han, Jiade
    Hong, Guangyu
    Tang, Lu
    Lu, Yiping
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 970 - 975
  • [48] Application of Dynamic Characteristic Analysis Technology for Stator End-winding of Large Capacity Turbo-generator
    Gao, Shuyou
    Wen, Lu
    Liao, Wei
    2009 THIRD INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL 1, PROCEEDINGS, 2009, : 669 - 671
  • [49] Tactics and technique of in-situ high efficiency dynamic balancing of large size turbo-generator set
    Lu, Song-Yuan
    Zhongguo Dianli/Electric Power, 2002, 35 (03):
  • [50] Damping Torque Coefficient Affected by Different Rotor Damping Structures of Turbo-generator during large disturbance
    Xu, Guorui
    Zhou, Jingdi
    Li, Zhiqiang
    Zhao, Haisen
    Cao, Zhiwei
    Wang, Jihao
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 1729 - 1734