Novel dual-channel-spacing WDM multi/demultiplexers based on phased-array waveguide grating

被引:0
|
作者
Lin, Wenhua [1 ]
Li, Haifeng [1 ]
Chen, Y.J. [1 ]
Dagenais, M. [1 ]
Stone, D. [1 ]
机构
[1] Univ of Maryland, Baltimore, United States
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:344 / 345
相关论文
共 50 条
  • [31] A novel algorithm in a linear phased array system for side lobe and grating lobe level reduction with large element spacing
    Khalilpour, Jafar
    Ranjbar, Javad
    Karami, Poorya
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2020, 104 (03) : 265 - 275
  • [32] A novel algorithm in a linear phased array system for side lobe and grating lobe level reduction with large element spacing
    Jafar Khalilpour
    Javad Ranjbar
    Poorya Karami
    Analog Integrated Circuits and Signal Processing, 2020, 104 : 265 - 275
  • [33] LOW-LOSS PHASED-ARRAY BASED 4-CHANNEL WAVELENGTH DEMULTIPLEXER INTEGRATED WITH PHOTODETECTORS
    AMERSFOORT, MR
    DEBOER, CR
    VERBEEK, BH
    DEMEESTER, P
    LOOYEN, A
    VANDERTOL, JJGM
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1994, 6 (01) : 62 - 64
  • [34] Multi-channel drive system of phased array based on DDS chips
    Zheng, Jianfeng
    Bai, Bichao
    Zhang, Han
    APPLIED ACOUSTICS, 2021, 182
  • [35] A Novel Calibration Method for Phased-Array Radar based on Element-wise Time Offsetting and Multi-Element Phase Toggle
    Magalhaes, Giorgio
    Leon, Julio
    de Menezes, Marcio
    2019 IEEE RADAR CONFERENCE (RADARCONF), 2019,
  • [36] Multi-channel WDM based on coupling between waveguide and micro-cavity
    杨春云
    徐旭明
    何灵娟
    OptoelectronicsLetters, 2010, 6 (03) : 218 - 221
  • [37] Multi-channel WDM based on coupling between waveguide and micro-cavity
    Yang C.-Y.
    Xu X.-M.
    He L.-J.
    Optoelectronics Letters, 2010, 6 (3) : 218 - 221
  • [38] 6.4-THz-spacing, 10-channel cyclic arrayed waveguide grating for T- and O-band coarse WDM
    Idris, Nazirul Afham
    Tsuda, Hiroyuki
    IEICE ELECTRONICS EXPRESS, 2016, 13 (07):
  • [39] PROSTATE CANCER DETECTION WITH MULTIPARAMETRIC MRI: IS THERE A DIFFERENCE BETWEEN THE 32-CHANNEL "PHASED-ARRAY" AND THE "DUAL-COIL" MRI?
    Porpiglia, Francesco
    Manfredi, Matteo
    Mele, Fabrizio
    Fiori, Cristian
    Bollito, Enrico
    De Pascale, Agostino
    Gned, Dario
    Dervishi, Najada
    Cirillo, Stefano
    Petracchini, Massimo
    Bertolo, Riccardo
    Amparore, Daniele
    Cattaneo, Giovanni
    Garrou, Diletta
    Checcucci, Enrico
    Veltri, Andrea
    ANTICANCER RESEARCH, 2016, 36 (05) : 2582 - 2582
  • [40] A novel DWDM inter leaver scheme based on phased-array wavelength demultiplexer with multimode interference couplers
    陆思
    严瑛白
    金国藩
    Chinese Optics Letters, 2004, (06) : 314 - 315