Application of Nuclear Track Detectors for the Measurement of Small Alpha-emitter Concentrations in Aluminum Foils.

被引:0
|
作者
Pitt, Eberhard [1 ]
Scharmann, Arthur [1 ]
Werner, Bernhard [1 ]
Selders, Matthias [1 ]
机构
[1] Univ Giessen, Physikalisches Inst,, Giessen, West Ger, Univ Giessen, Physikalisches Inst, Giessen, West Ger
来源
Atomkernenergie, Kerntechnik | 1985年 / 46卷 / 02期
关键词
DOSIMETERS - NEUTRONS - Detectors - RADIATION DETECTORS;
D O I
暂无
中图分类号
学科分类号
摘要
Expensive systems are available to detect impurities in the range of ppb in solids. Solid-state nuclear track detectors supply a simple facility to detect very low concentrations of alpha -radiators in solids. A method is described to estimate activities per unit area of about 2 decays/cm**2d (2. 3 multiplied by 10** minus **5 Bq/cm**2) on the surface of metallic foils. In aluminum foils contaminations of 15 ppb uranium have been detected by this method.
引用
收藏
页码:122 / 124
相关论文