POSITION RESOLUTION IN SILICON SAMPLING CALORIMETERS.

被引:0
|
作者
Coon, D.D. [1 ]
Liu, L.Z. [1 ]
机构
[1] Univ of Pittsburgh, Pittsburgh, PA,, USA, Univ of Pittsburgh, Pittsburgh, PA, USA
来源
关键词
PHYSICS - High Energy - RADIATION DETECTORS;
D O I
暂无
中图分类号
学科分类号
摘要
Due to the coupling between closely spaced detectors, the position resolution of a silicon sampling calorimeter can be degraded. In a capacitance coupling model, a Green's function is found which quantitatively describes signal spreading over two-dimensional detector arrays. The result provides some theoretical guidance in choosing calorimeter parameters to get the best performance.
引用
收藏
页码:457 / 460
相关论文
共 50 条
  • [1] POSITION RESOLUTION IN SILICON SAMPLING CALORIMETERS
    COON, DD
    LIU, LZ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 251 (03): : 457 - 460
  • [2] COMPARISON OF DIFFERENT SILICON SAMPLING CALORIMETERS.
    Lemeilleur, F.
    Leroy, C.
    Rancoita, P.G.
    Seidman, A.
    Nuclear instruments and methods in physics research, 1985, A241 (2-3): : 600 - 601
  • [3] COMPARISON OF THE ELECTROMAGNETIC SHOWER DEVELOPMENT IN SILICON SAMPLING CALORIMETERS.
    Levman, G.M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1986, B16 (4-5) : 407 - 410
  • [4] ON THE ENERGY RESOLUTION OF URANIUM AND OTHER HADRON CALORIMETERS.
    Wigmans, Richard
    1600, (A259):
  • [5] BACKGROUND RATES IN SILICON DETECTORS USED IN URANIUM CALORIMETERS.
    Ellison, J.A.
    Barber, G.J.
    Hall, G.
    Websdale, D.M.
    Nuclear instruments and methods in physics research, 1984, A235 (02): : 244 - 248
  • [6] The principles of differential air calorimeters.
    Bothe, W
    PFLUGERS ARCHIV FUR DIE GESAMTE PHYSIOLOGIE DES MENSCHEN UND DER TIERE, 1939, 241 (5/6): : 630 - 640
  • [7] MODELING RESPONSE VARIATION FOR RADIOMETRIC CALORIMETERS.
    Mayer, Richard L.
    Nuclear materials management, 1986, 15 : 237 - 241
  • [8] PERFORMANCE OF URANIUM LIQUID ARGON CALORIMETERS.
    Franzini, Paolo
    Nuclear instruments and methods in physics research, 1986, A263 (01): : 78 - 83
  • [9] SYSTEMATIC INVESTIGATION OF THE ELECTROMAGNETIC ENERGY RESOLUTION ON SAMPLING FREQUENCY USING SILICON CALORIMETERS
    BOSETTI, M
    FURETTA, C
    LEROY, C
    PENSOTTI, S
    PENZO, A
    RANCOITA, PG
    RATTAGGI, M
    REDAELLI, M
    SALVATO, G
    TERZI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (02): : 244 - 249
  • [10] OPTICAL FIBER READOUT FOR SCINTILLATOR CALORIMETERS.
    Kryshkin, V.I.
    Ronzhin, A.T.
    Nuclear instruments and methods in physics research, 1986, A247 (03): : 583 - 585