Design of patient shielding to reduce the effects of out-of-field radioactivity in 3D PET

被引:0
|
作者
Daube-Witherspoon, M.E. [1 ]
Belakhlef, A. [1 ]
Green, S.L. [1 ]
Zanzi, I. [1 ]
机构
[1] Natl Inst of Health, Bethesda, United States
关键词
Brain - Cameras - Image reconstruction - Radiation effects - Radiation shielding - Three dimensional computer graphics;
D O I
暂无
中图分类号
学科分类号
摘要
Randoms, deadtime, and scatter from activity outside the scanner are potential sources of bias and noise in volume positron emission tomography (PET). Additional scanner shielding has been shown to reduce the effects of out-of-field activity (OFA) in brain imaging. We have undertaken the design of OFA shielding that is also effective for body imaging. The shielding consists of lead sheet that is molded around, but not touching, a subject to surround the area(s) of OFA. The effectiveness of the shielding at reducing the singles flux and scattered coincidences from OFA was studied on the GE Advance PET scanner as a function of shielding thickness and axial width, patient-shielding gap, and axial source location. The optimal design was found to be 3-6-mm thick lead sheet that extends 10-15 cm from the OFA towards the scanner with a small (1-2 cm) gap between the patient and shielding allowed. With such shielding, singles are reduced by 50-70% for source positions out to 25 cm from the edge of the axial field of view, while scatter is reduced by 65-90%.
引用
收藏
页码:1237 / 1242
相关论文
共 50 条
  • [21] Extra shielding for improved signal-to-noise in 3D whole-body PET
    Laforest, R
    Cutler, PD
    Daube-Witherspoon, ME
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1359 - 1362
  • [22] The effects of 3D printing in design thinking and design education
    Greenhalgh, Scott
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2016, 14 (04) : 752 - 769
  • [23] Design of an architecture for real-time 3D PET imaging
    Di Sciascio, E
    Manni, AR
    Guzzardi, R
    REAL-TIME IMAGING, 1998, 4 (04) : 255 - 262
  • [24] Design and manufacture of a 3D printed phantom for PET quality control
    Robinson, J.
    Rushforth, D.
    Murray, I.
    Flux, G.
    Gear, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S14 - S14
  • [25] Out-of-field doses in pediatric craniospinal irradiations with 3D-CRT, VMAT, and scanning proton radiotherapy: A phantom study
    Majer, Marija
    Ambrozova, Iva
    Davidkova, Marie
    De Saint-Hubert, Marijke
    Kasabasic, Mladen
    Knezevic, Zeljka
    Kopec, Renata
    Krzempek, Dawid
    Krzempek, Katarzyna
    Miljanic, Saveta
    Mojzeszek, Natalia
    Versic, Ivan
    Stolarczyk, Liliana
    Harrison, Roger M.
    Olko, Pawel
    MEDICAL PHYSICS, 2022, 49 (04) : 2672 - 2683
  • [26] Simulation study of patient and crystal scatter in 3D PET for various crystals
    Staelens, S
    Vandenberghe, S
    Glick, SJ
    D'Asseler, Y
    Lemahieu, I
    Van de Walle, R
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3574 - 3578
  • [27] Design of Seamless Knitted Radiation Shielding Garments with 3D Body Scanning Technology
    Maghrabi, Huda Ahmed
    Vijayan, Arun
    Wang, Lijing
    Deb, Pradip
    PROCEEDINGS OF THE 1ST INTERNATIONAL DESIGN TECHNOLOGY CONFERENCE, DESTECH2015, 2015, 20 : 123 - 132
  • [28] Development of 3D DMFC Model for Flow Field Design
    Kim, Hongseong
    Danilov, Valeri A.
    Lim, Jongkoo
    Moon, Il
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2007, 45 (01): : 93 - 102
  • [29] Application design of 3D printing technology in the field of Architecture
    Zhang, Yuang
    Lu, Hongqian
    Chen, Hongwei
    Sun, Meiyu
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 3511 - 3515
  • [30] Automatic design of 3D uniform-field electrode
    Tang Y.
    Tan R.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (11): : 2561 - 2565