Validation of real-time continuous perfusion measurement

被引:0
|
作者
Thermal Technologies, Inc., Cambridge, MA, United States [1 ]
机构
来源
关键词
Blood - Flow measurement - Patient treatment - Real time systems - Temperature measurement - Thermistors - Tissue;
D O I
10.1007/bf02347053
中图分类号
学科分类号
摘要
Perfusion, the rate at which blood in tissue is replenished at the capillary level, is a primary factor in the transport of heat, drugs, oxygen and nutrients. While there have been many measurement techniques proposed, most do not lend themselves to routine, continuous and real-time use. A minimally invasive probe, called the thermal diffusion probe (TDP), which uses a self-heated thermistor to measure absolute perfusion continuously and in real time, was validated at low flows with the microsphere technique. In 27 rabbits, simultaneous TDP measurements were made in liver from 0 to 60 ml min-1 100 g-1. The TDP perfusion correlated well with the microspheres (R2 = 0.898) and the agreement between techniques is very good with a slope close to unity (0.921) and an intercept close to zero (0.566 ml min-1 100 g-1). Variability between the two techniques was primarily due to the sampling error from the microsphere 'snap shot' of periodic blood flow when compared with the continuous TDP perfusion measurement. The ability to quantify local perfusion continuously and in real time may have a profound impact on patient management in a number of clinical areas such as organ transplantation, neurosurgery, oncology and others, in which quantitative knowledge of perfusion is of value.
引用
收藏
页码:319 / 325
相关论文
共 50 条
  • [21] Model Validation and Real-Time Process Control of a Continuous Flow Ohmic Heater
    Oluwole-ojo, Oluwaloba
    Javed, Tasmiyah
    Howarth, Martin
    Xu, Xu
    O'Brien, Alexander
    Zhang, Hongwei
    MODELLING, 2024, 5 (03): : 752 - 775
  • [22] AUDITING REAL-TIME MEASUREMENT
    GARDNER, B
    GLAZEBROOK, TJ
    MORRISON, WR
    RYAN, WH
    WILLIAMS, ML
    AGA 1989 OPERATING SECTION PROCEEDINGS, 1989, : 513 - 519
  • [23] AN EMPHASIS ON REAL-TIME MEASUREMENT
    不详
    MANUFACTURING ENGINEERING, 1982, 89 (05): : 34 - 35
  • [24] Real-time temperature measurement
    Atlas Material Testing Technology LLC, Chicago, IL
    不详
    Finsh. Today, 2008, 2 (28-31):
  • [25] The Bowman Perfusion Monitor: A Novel Technology for Real-Time Measurement of Tissue Microperfusion.
    Pomposelli, James J.
    Li, Vivian V.
    Tymm, Michael
    Simpson, Mary Ann
    Bowman, H. Frederick
    Pomfret, Elizabeth A.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 : 697 - 698
  • [26] Real-time lung weight measurement during clinical ex vivo lung perfusion
    Sakanoue, Ichiro
    Okamoto, Toshihiro
    Ayyat, Kamal S.
    Yun, James J.
    Tantawi, Abdel Moneim
    McCurry, Kenneth R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (12): : 2008 - 2017
  • [27] Validation of a sensor-system for real-time measurement of mineralized nitrogen in soils
    Vikuk, Veronika
    Spirkaneder, Andrea
    Noack, Patrick
    Duemig, Alexander
    SMART AGRICULTURAL TECHNOLOGY, 2024, 7
  • [28] Real-Time Gas Measurement Validation Benefits from Improvements in Computing Equipment
    Treat, Russel W.
    Pipeline and Gas Journal, 2003, 230 (10): : 52 - 55
  • [29] Surface Temperature Measurement of In-Vessel Components and Its Real-Time Validation
    Herrmann, A.
    Sieglin, B.
    Faitsch, M.
    FUSION SCIENCE AND TECHNOLOGY, 2016, 69 (03) : 569 - 579
  • [30] Validation of real-time PCR methods for measurement of skin barrier biomarkers in vitro
    Farmer, T. L.
    McPhail, S. J.
    Kincaid, E. M.
    Holleran, W. M.
    Mills, K. J.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2007, 127 : S78 - S78