Validation of real-time continuous perfusion measurement

被引:0
|
作者
Thermal Technologies, Inc., Cambridge, MA, United States [1 ]
机构
来源
关键词
Blood - Flow measurement - Patient treatment - Real time systems - Temperature measurement - Thermistors - Tissue;
D O I
10.1007/bf02347053
中图分类号
学科分类号
摘要
Perfusion, the rate at which blood in tissue is replenished at the capillary level, is a primary factor in the transport of heat, drugs, oxygen and nutrients. While there have been many measurement techniques proposed, most do not lend themselves to routine, continuous and real-time use. A minimally invasive probe, called the thermal diffusion probe (TDP), which uses a self-heated thermistor to measure absolute perfusion continuously and in real time, was validated at low flows with the microsphere technique. In 27 rabbits, simultaneous TDP measurements were made in liver from 0 to 60 ml min-1 100 g-1. The TDP perfusion correlated well with the microspheres (R2 = 0.898) and the agreement between techniques is very good with a slope close to unity (0.921) and an intercept close to zero (0.566 ml min-1 100 g-1). Variability between the two techniques was primarily due to the sampling error from the microsphere 'snap shot' of periodic blood flow when compared with the continuous TDP perfusion measurement. The ability to quantify local perfusion continuously and in real time may have a profound impact on patient management in a number of clinical areas such as organ transplantation, neurosurgery, oncology and others, in which quantitative knowledge of perfusion is of value.
引用
收藏
页码:319 / 325
相关论文
共 50 条
  • [1] Validation of real-time continuous perfusion measurement
    Martin, GT
    Bowman, HF
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (03) : 319 - 325
  • [2] Validation of real-time continuous perfusion measurement
    G. T. Martin
    H. F. Bowman
    Medical and Biological Engineering and Computing, 2000, 38 : 319 - 325
  • [3] CONTINUOUS REAL-TIME INTRAOPERATIVE WAVEFRONT MEASUREMENT
    Chang, David F.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 65 - 65
  • [4] Continuous real-time measurement of fluorescence lifetimes
    Trabesinger, W
    Hübner, CG
    Hecht, B
    Wild, UP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08): : 3122 - 3124
  • [5] Continuous and real-time blood perfusion monitoring in prefabricated flaps
    Maitz, PKM
    Khot, MB
    Mayer, HF
    Martin, GT
    Pribaz, JJ
    Bowman, HF
    Orgill, DP
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2004, 20 (01) : 35 - 41
  • [6] THE ACCURACY OF CONTINUOUS REAL-TIME GLUCOSE MEASUREMENT BY MICRODIALYSIS
    Blixt, C.
    Rooyackers, O.
    Wernerman, J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S99 - S99
  • [7] A Real-Time, Telemetric Method for Continuous Measurement of Portal Pressures
    Schwartz, Jason
    Rohrwasser, Andreas
    Hillas, Elaine
    Hatch, Jenny
    Sorensen, John
    Gayowski, Timothy
    Hutson, William
    Lalouel, Jean-Marc
    JOURNAL OF SURGICAL RESEARCH, 2010, 159 (02) : 618 - 621
  • [8] An FPGA Correlator for Continuous Real-Time Measurement of Particulate Flow
    Lee, Peter
    Adefila, Kehinde
    Yan, Yong
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2183 - 2186
  • [9] Implantable Oxygen Platform for Continuous, Real-time Detection of Vascular Perfusion and Ischemia
    Ibrahim, Mohamed M.
    Schweller, Ryan M.
    Mohammed, Mahmoud M.
    Powers, David B.
    Klitzman, Bruce
    WOUND REPAIR AND REGENERATION, 2018, 26 (01) : A8 - A8
  • [10] Modeling and validation of the real-time
    Scheduler, Mach
    Arakawa, Hiroshi
    Katcher, Daniel I.
    Strosnider, Jay K.
    Tokuda, Hideyuki
    Performance Evaluation Review, 1993, 21 (01):