DEAD-TIME CORRECTION METHOD FOR SHORT-LIVED RADIOISOTOPES USING MEASURED PEAK AREAS.

被引:0
|
作者
Kennedy, Gregory
机构
关键词
MATHEMATICAL STATISTICS - NEUTRONS;
D O I
暂无
中图分类号
学科分类号
摘要
A computer based method has been developed for the correction of counting losses due to ADC dead-time and pulse pile-up in gamma-ray spectrometry. The method is designed specifically for neutron activation analysis and can handle a mixture of short-lived radionuclides, where the dead-time decreases substantially during the measurement period. Once the system is calibrated, the only input values needed to correct a spectrum are the measured peak areas and the counting time.
引用
收藏
页码:207 / 210
相关论文
共 50 条
  • [41] Development of a method for screening short-lived proteins using green fluorescent protein
    Xin Jiang
    Philip Coffino
    Xianqiang Li
    Genome Biology, 5
  • [42] Correction of the isomeric-state effect using the double dead-time method in the activity measurement of75Se
    Chauvenet, B.
    Bouchard, J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A339 (1-2) : 394 - 397
  • [43] CORRECTION OF THE ISOMERIC-STATE EFFECT USING THE DOUBLE DEAD-TIME METHOD IN THE ACTIVITY MEASUREMENT OF SE-75
    CHAUVENET, B
    BOUCHARD, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 394 - 397
  • [44] Statistical analysis of dead-time system using a deterministic equivalent modeling method
    Pham Luu Trung Duong
    Lee, Moonyong
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2011, 6 (03) : 369 - 378
  • [45] Innovative dead-time correction and background subtraction for neutron multiplicity measurements using neural networks
    Garcia-Duarte, Jeremias
    Mishnayot, Yonatan
    Tamashiro, Aaron S.
    Lawrence, Jackson R.
    Harke, Jason T.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [46] Improvement of the determination of radioactivity concentrations of short-lived radioisotopes with the time-dependent leakage model of VVER-type nuclear reactor
    Szarvas, Csongor Kristof
    Radocz, Gabor
    Gerenyi, Anita
    Rozmanitz, Peter Jakab
    Szaloki, Imre
    ANNALS OF NUCLEAR ENERGY, 2025, 211
  • [47] Simulation of radiotracer method for diffusion studies using short-lived radioactive nuclear beams
    Jeong, SC
    Katayama, I
    Kawakami, H
    Ishiyama, H
    Miyatake, H
    Sataka, M
    Iwase, A
    Okayasu, S
    Sugai, H
    Ichikawa, S
    Nishio, K
    Sugiyama, Y
    Yahagi, M
    Takada, K
    Watanabe, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 212 : 483 - 488
  • [48] MEASUREMENT OF SHORT-LIVED FLUORESCENCE DECAY USING SINGLE PHOTON-COUNTING METHOD
    LEWIS, C
    WARE, WR
    DOEMENY, LJ
    NEMZEK, TL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (02): : 107 - 114
  • [49] Exploring a Method for Measuring Copper Absorption Using a Short-Lived Isotope (64 Cu)
    Tasker, P.
    Sharma, H.
    Braganza, J. M.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 107 - 107
  • [50] Impact of dead-time correction method on 177Lu quantitative SPECT and dosimetry in personalized PRRT
    Desy, A.
    Bouvet, G. F.
    Beauregard, J. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S72 - S73