摘要
This paper proposes a new error compensation circuit which can be used for a clamp-current transformer. The error-compensation circuit is installed only on the secondary circuit and therefore it is free from electrical and structural restrictions imposed on the main current transformer. In addition, it is possible to reduce the size of the error-compensation circuit because the magnitude of secondary current is usually small. In particular, it should be noted that the phase angle of the clamp current transformer is reduced to a very low level. The conventional error-compensation circuit is presented and the newly proposed error-compensation circuit is discussed. Stability of the proposed error-compensation circuit is discussed and experimental results are given.
引用
收藏
页码:14 / 21
相关论文
共 50 条
  • [21] A method for high-precision measuring differential transformer asymmetry
    Yang, Xiao-Tian
    Hu, Ming
    Wang, Cheng-Rui
    Li, Duo
    Chen, De-Cong
    Ouyang, Chao-Li
    Bai, Yan-Zheng
    Qu, Shao-Bo
    Zhou, Ze-Bing
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (06):
  • [22] A Resistorless High-Precision Compensated CMOS Bandgap Voltage Reference
    Zhou, Ze-Kun
    Shi, Yue
    Wang, Yao
    Li, Nie
    Xiao, Zhiping
    Wang, Yunkun
    Liu, Xiaolin
    Wang, Zhuo
    Zhang, Bo
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2019, 66 (01) : 428 - 437
  • [23] High-precision and large-capacity potential transformer
    Hu, Xiaoguang
    Wang, Banhai
    Chen, Yunping
    Song, Kuigang
    Gaodianya Jishu/High Voltage Engineering, 2000, 26 (04): : 73 - 74
  • [24] A High-Precision Error Calibration Technique for Current Transformers under the Influence of DC Bias
    Dang, Sanlei
    Xiao, Yong
    Wang, Baoshuai
    Zhang, Dingqu
    Zhang, Bo
    Hu, Shanshan
    Song, Hongtian
    Xu, Chi
    Cai, Yiqin
    ENERGIES, 2023, 16 (24)
  • [25] Analysis and Research on A High-precision Remote Transformer Calibration Device Considering The Influence of Excitation Current
    Fu, Jiliang
    Wang, Quan
    Qi, Cong
    Zhao, Qiancheng
    Yu, Xueqin
    Qi, Xin
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [26] High-precision machining by measurement and compensation of motion error
    Kono, Daisuke
    Matsubara, Atsushi
    Yamaji, Iwao
    Fujita, Tomoya
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2008, 48 (10): : 1103 - 1110
  • [27] Measuring the angles and pyramidal error of high-precision prisms
    JaramilloNunez, A
    RobledoSanchez, C
    OPTICAL ENGINEERING, 1997, 36 (10) : 2868 - 2871
  • [28] Thermal effect on the dynamic error of a high-precision worktable
    Zou, Haitian
    Wang, Baolin
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2017, 17 (02) : 336 - 343
  • [29] HIGH-PRECISION DC-CURRENT SOURCE
    ERNE, SN
    LUTHER, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1975, 24 (04) : 345 - 348
  • [30] A 1.8-V high-precision compensated CMOS bandgap reference
    Weng, Ro-Min
    Hsu, Xie-Ren
    Kuo, Yue-Fang
    2005 IEEE CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS, PROCEEDINGS, 2005, : 271 - 273