HIGH-VOLTAGE HIGH-POWER RESISTIVE DIVIDER FOR TFTR NEUTRAL-BEAM POWER SUPPLY.

被引:0
|
作者
Phillips, Samuel R. [1 ]
机构
[1] Portola Valley, CA 94025, United States
关键词
NUCLEAR REACTORS; THERMONUCLEAR; -; Components;
D O I
暂无
中图分类号
学科分类号
摘要
The neutral-beam source at the Tokamak Fusion Test Reactor (TFTR) requires a voltage divider to supply the gradient grid. The requirements are simple, but stringent: it must dissipate 576 kW of peak power at 120 kV dc. Average power is 19. 2 kW. A description is given of a resistive divider, indirectly water cooled, which has been successfully developed for this purpose. The divider is unusually large physically, weighing 1290 kg when filled, and its cooling system is believed to be unique. The heat capacity of the system reliably averages the pulse power, and there are no pumps or other moving parts. Operation of the system, which is intrinsically self-regulating, is relatively unaffected by leakage or noncondensible gas.
引用
收藏
页码:467 / 469
相关论文
共 50 条
  • [31] High-voltage insulation of a high-power pulse transformer
    Ratakhin N.A.
    Fedushchak V.F.
    Russian Physics Journal, 1999, 42 (12) : 996 - 1000
  • [32] HIGH-POWER HIGH-VOLTAGE PULSE GENERATOR.
    Verkhovskii, S.Ya.
    Lyulyaev, A.V.
    Flat, F.A.
    Instruments and experimental techniques New York, 1985, 28 (4 pt 1): : 841 - 843
  • [33] PARTICLE CONFINEMENT DURING HIGH-POWER NEUTRAL-BEAM INJECTION IN JFT-2 TOKAMAK
    MATSUMOTO, H
    KIMURA, H
    SENGOKU, S
    SUZUKI, N
    OHASA, K
    YAMAMOTO, S
    NUCLEAR FUSION, 1982, 22 (06) : 840 - 843
  • [34] ION HEATING WITH HIGH-POWER PERPENDICULAR NEUTRAL-BEAM INJECTION IN THE POLOIDAL DIVERTOR EXPERIMENT (PDX)
    HAWRYLUK, RJ
    ARUNASALAM, V
    BELL, M
    BITTER, M
    BOL, K
    BRAU, K
    DAVIS, S
    DYLLA, F
    EUBANK, H
    FINKENTHAL, M
    FONCK, R
    GOLDSTON, R
    GREK, B
    HUGILL, J
    JOHNSON, D
    KAITA, R
    KAYE, S
    KUGEL, H
    MANSFIELD, D
    MANOS, D
    MCGUIRE, K
    MCCANN, R
    MCCUNE, D
    MUELLER, D
    OKABAYASHI, M
    OWENS, K
    REUSCH, M
    SAUTHOFF, N
    SCHILLING, G
    SCHMIDT, G
    SESNIC, S
    SUCKEWER, S
    TAIT, G
    TAKAHASHI, H
    TENNEY, F
    YAMAZAKI, K
    PHYSICAL REVIEW LETTERS, 1982, 49 (05) : 326 - 329
  • [35] High-voltage Cable in Municipal Electricity Supply.
    Schmidhuber, Paul M.
    Elektrizitatswirtschaft, 1980, 79 (26): : 1024 - 1033
  • [36] HIGH-VOLTAGE POWER SUPPLY FOR GEM DETECTORS
    Gaska, Michal
    Kasprowicz, Grzegorz
    Linczuk, Pawel
    Krawczyk, Rafal D.
    Wojenski, Andrzej
    Zabolotny, Wojciech
    Pozniak, Krzysztof
    Kolasinski, Piotr
    Chernyshova, Maryna
    Czarski, Tomasz
    Kowalska-Strzeciwilk, Ewa
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2018, 11 (04) : 781 - 785
  • [37] High-voltage power supply distribution system
    Kobal, M.
    Golob, Damjan
    Kusterle, Tilen
    Pelko, Miha
    Plesko, Mark
    Podborsek, Aljaz
    EPAC 2008 - Contributions to the Proceedings, 2008, : 3708 - 3710
  • [38] HIGH-VOLTAGE REGULATED POWER-SUPPLY
    BAGINSKII, BA
    MAKAREVICH, VN
    SHTEIN, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (03) : 737 - 738
  • [39] REGULATED HIGH-VOLTAGE POWER-SUPPLY
    KIBITKIN, VV
    NEKRASOV, AM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1988, 31 (02) : 389 - 390
  • [40] PRECISION HIGH-VOLTAGE POWER-SUPPLY
    KANTOR, EL
    LANTSOV, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (06) : 1687 - 1687