A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. Here charcoal acts as a radon collector from the air and the track-etch detector as a recorder of alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon utilizing Deodorant activated charcoal (TOK, Yugoslavia) and CR-39 track-etch detector is 1.4 tracks cm-2/Bqm-3 d, which is about eight times higher than that obtained with a standard track-etch dosimeter.
引用
收藏
页码:423 / 424
相关论文
共 50 条
  • [1] A NEW TECHNIQUE FOR RADON MEASUREMENT BASED ON A COMBINATION OF A TRACK-ETCH DETECTOR AND ACTIVATED-CHARCOAL
    SUTEJ, T
    KRIZMAN, M
    ILIC, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 423 - 424
  • [2] A passive radon dosimeter based on the combination of a track etch detector and activated charcoal
    Van Deynse, A
    Cosma, C
    Poffijn, A
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 325 - 330
  • [3] Parallel track-etch detector arrangement for radon measurement in soil
    Turek, K
    Bednar, J
    Neznal, M
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 751 - 754
  • [4] INTERLABORATORY CALIBRATION OF TRACK-ETCH DETECTORS FOR THE MEASUREMENT OF RADON AND RADON DAUGHTER LEVELS
    JOJO, PJ
    KHAN, AJ
    TYAGI, RK
    RAMACHANDRAN, TV
    RAMU, MCS
    PRASAD, R
    RADIATION MEASUREMENTS, 1994, 23 (04) : 715 - 724
  • [5] THE TRACK-ETCH DETECTOR OF THE MACRO EXPERIMENT
    不详
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 331 - 336
  • [6] INDOOR RADON MEASUREMENTS WITH TRACK-ETCH DETECTORS
    OSWALD, RA
    ALTER, HW
    GINGRICH, JE
    HEALTH PHYSICS, 1982, 43 (01): : 122 - 122
  • [7] RESPONSE OF TRACK-ETCH DOSIMETERS TO ENVIRONMENTAL RADON
    SUTEJ, T
    ILIC, R
    NAJZER, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 547 - 550
  • [8] MEASUREMENT OF RADON AND THORON PRESENT IN THE ENVIRONMENT USING NUCLEAR TRACK ETCH DETECTOR TECHNIQUE
    RAMACHANDRAN, TV
    LALIT, BY
    MISHRA, UC
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 11 (4-5): : 245 - 249
  • [9] MODELING A 222Rn MEASUREMENT TECHNIQUE BASED ON ABSORPTION IN POLYCARBONATES AND TRACK-ETCH COUNTING
    Pressyanov, Dobromir S.
    HEALTH PHYSICS, 2009, 97 (06): : 604 - 612
  • [10] ANGULAR DEPENDENCE OF TRACK-ETCH DETECTOR HARZLAS TD-1
    Ambrozova, Iva
    Brabcova, Katerina Pachnerova
    Shurshakov, Vyacheslav A.
    Tolochek, Raisa, V
    Kodaira, Satoshi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (2-3) : 219 - 223