Finite element modelling of a residual lower-limb in a prosthetic socket: A survey of the development in the first decade

被引:0
|
作者
Zhang, Ming [1 ]
Mak, Arthur F.T. [1 ]
Roberts, V.C. [2 ]
机构
[1] Rehabilitation Engineering Centre, Hong Kong Polytech. Univ., Hong Kong, Kowloon, Hong Kong
[2] Dept. of Med. Eng. and Physics, King's Coll. Sch. Med. Dent., D., London, United Kingdom
来源
Medical Engineering and Physics | 1998年 / 20卷 / 05期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:360 / 373
相关论文
共 50 条
  • [1] Finite element modelling of a residual lower-limb in a prosthetic socket: a survey of the development in the first decade
    Zhang, M
    Mak, AFT
    Roberts, VC
    MEDICAL ENGINEERING & PHYSICS, 1998, 20 (05) : 360 - 373
  • [2] Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket
    SilverThorn, MB
    Childress, DS
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1997, 34 (02): : 171 - 186
  • [3] METHOD FOR THE DESIGN AND ANALYSIS OF A NONLINEAR ANISOTROPIC LOWER-LIMB PROSTHETIC SOCKET
    SOH, AK
    SOH, CK
    LAU, WS
    JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (06): : 470 - 476
  • [4] Three-dimensional finite element analyses on the transtibial residual limb and its prosthetic socket
    Hong Kong Polytechnic Univ, Hong Kong, Hong Kong
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2000, 17 (04): : 403 - 406
  • [5] Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
    Lee, WCC
    Zhang, M
    Jia, XH
    Cheung, JTM
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (08) : 655 - 662
  • [6] A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures
    Peery, Jeffrey T.
    Klute, Glenn K.
    Blevins, Joanna J.
    Ledoux, William R.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (03) : 336 - 343
  • [7] State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: A review
    Mak, AFT
    Zhang, M
    Boone, DA
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2001, 38 (02): : 161 - 173
  • [8] Using mechanical testing to assess the effect of lower-limb prosthetic socket texturing on longitudinal suspension
    Quinlan, Julia
    Yohay, Jessica
    Subramanian, Vasanth
    Poziembo, Brad
    Fatone, Stefania
    PLOS ONE, 2020, 15 (08):
  • [9] Development of a non-linear finite element modelling of the below-knee prosthetic socket interface
    Zhang, M.
    Lord, M.
    Turner-Smith, A.R.
    Roberts, V.C.
    Medical Engineering and Physics, 1995, 17 (08): : 559 - 566
  • [10] Key considerations for finite element modelling of the residuum-prosthetic socket interface
    Steer, J. W.
    Worsley, P. R.
    Browne, M.
    Dickinson, Alex
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2021, 45 (02) : 138 - 146