ANALYSIS OF THE CHARACTERISTICS OF A DOUBLE-STAR SYNCHRONOUS GENERATOR WITH RECTIFIER LOAD.

被引:0
|
作者
Li, Xingyuan [1 ]
Huang, Yaoqun [1 ]
Xie, Yingpu [1 ]
Su, Yide [1 ]
机构
[1] Tsinghua Univ, China, Tsinghua Univ, China
关键词
ELECTRIC LOADS - ELECTRIC RECTIFIERS;
D O I
暂无
中图分类号
学科分类号
摘要
The characteristics of a double-star synchronous generator with rectifier load have been studied from the fundamental machine equations. The generator has two stator windings shifted by 30 or 0 electrical degrees, which with their bridges can be connected either in series or in parallel. Therefore, the double-star synchronous generator with rectifier load can form four operating modes. From the fundamental machine equations, expressions of displacement angles and commutation angles are derived under these operating modes. The characteristics of a double-star synchronous generator with rectifier load can be predicted from given load current, field current generator speed, bridge delay angle and parameters. Theoretical results are compared with experimental results.
引用
收藏
页码:33 / 45
相关论文
共 50 条
  • [21] Double-star 12-pulse rectifier based on full-wave inter-phase reactor
    Wang J.
    Yao X.
    Feng S.
    Guan Q.
    Shen L.
    Yang S.
    1600, Electric Power Automation Equipment Press (40): : 96 - 102
  • [22] Approximate zero-current commutation and low-harmonic double-star rectifier with circulating current extraction
    Wang J.
    Yang S.
    Yang W.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2016, 36 (08): : 115 - 121
  • [23] Fault tolerant and minimum loss control of double-star synchronous machines under open phase conditions
    Shamsi-Nejad, Mohammad-Ali
    Nahid-Mobarakeh, Babak
    Pierfederici, Serge
    Meibody-Tabar, Farid
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (05) : 1956 - 1965
  • [24] Decoupled d-q Model of Double-Star Interior-Permanent-Magnet Synchronous Machines
    Kallio, Samuli
    Andriollo, Mauro
    Tortella, Andrea
    Karttunen, Jussi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) : 2486 - 2494
  • [25] Features Analysis of Partial Demagnetization Faults in the 6-phase PM Synchronous Generator with Rectifier Load System
    Wang, Binghui
    Sun, Yuguang
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS, ENVIRONMENT, BIOTECHNOLOGY AND COMPUTER (MMEBC), 2016, 88 : 1499 - 1505
  • [26] Effects of leakage inductance on the input current of double-star diode rectifier with active inter-phase reactor
    Wang, J.
    Yang, S.
    SCIENTIA IRANICA, 2017, 24 (06) : 3193 - 3203
  • [27] Stability of a synchronous generator with diode-bridge rectifier and back-EMF load
    Weiming, M.
    An, H.
    Dezhi, L.
    Gaifan, Z.
    IEEE Power Engineering Review, 2000, 20 (05):
  • [28] Stability of a synchronous generator with diode-bridge rectifier and back-emf load
    Ma, WM
    Hu, A
    Liu, DZ
    Zhang, GF
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (04) : 458 - 463
  • [29] NON-STATIONARY BEHAVIOR EQUATIONS OF A SYNCHRONOUS GENERATOR SUPPLYING A LOAD ACROSS A RECTIFIER
    KISELEV, PV
    KHODZHAEV, KS
    ELECTRICAL TECHNOLOGY, 1983, (02): : 18 - 32
  • [30] Stability of a synchronous generator with diode-bridge rectifier and back-emf load
    Ma, WM
    Hu, A
    Liu, DZ
    Zhang, GF
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 609 - 615