NEW TYPES OF FIRE RETARDANT MATERIALS AND THEIR APPLICATION TO FIRE PROTECTION OF CABLES.

被引:0
|
作者
Yabuki, T.
Koide, Y.
Kaide, T.
Ichikawa, K.
Takada, M.
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The increasing need for preventing fire spreading through electric wire and cable lines has focused attention on the fire retardant material. Up to now, intumescent or nonintumescent coating compositions have been most widely used for that purpose. However, highly effective and economical fire prevention for electric lines was not found feasible with such coating compositions alone, without a suitable approach to handle the lines in accordance with the particular conditions involved. Taking account of various installation line of wire and cable, a new series of intumescent materials based on polymers and/or oligomes has been developed. These materials are in the form of a jacket, sheet, tube, self-bonding rubber-like tape, and a putty of nonhardening type for use in wall and floor penetrating bores and/or ducts for lines. Excellent fire-retardancy is experimentally observed on the cable covered with sheet, tube, tape or jacket, and on the cable installed in the penetrating bore where inlet and exit are sealed with the putty as a flame barrier. Effective and economical fire prevention can be assured by using the presently developed materials in suitable combination in accordance with line conditions.
引用
收藏
页码:56 / 71
相关论文
共 50 条
  • [21] FIRE PROTECTION OF CABLES IN CENTRAL GENERATING STATIONS
    NAMGNE, R
    ASHBAUGH, L
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 326 - 326
  • [22] PROTECTION OF CABLES AT RISK FROM EXPOSURE TO FIRE
    CREW, EW
    ELECTRONICS AND POWER, 1980, 26 (03): : 229 - 231
  • [23] PREVENTIVE FIRE PROTECTION FOR CABLES IN LARGE PLANTS
    WERSCH, HJ
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1975, 27 (3-4): : 81 - 81
  • [24] Examination of Insulation in Fire Retardant Cables by Time Domain Methods
    Vary, Michal
    Lelak, Jaroslav
    Durman, Vladimir
    Packa, Juraj
    PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 289 - 292
  • [25] Innovative insulation solution for zero halogen fire retardant cables
    Sawyer, Dudley
    Artingstall, Lai Ping
    Preston, Joe
    Dell, Steve
    Cochard, Severine
    Wire, 1997, 47 (03): : 43 - 44
  • [26] Fire retardant property of electric wires and cables by cone calorimeter
    Wang Yong
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 1470 - 1474
  • [27] Fire Protection of Building Constructions with the Use of Fire-Retardant Intumescent Compositions
    Eremina, Tatiana
    Korolchenko, Dmitry
    BUILDINGS, 2020, 10 (10) : 1 - 14
  • [28] Influence of graphene on fire protection of intumescent fire retardant coating for steel structure
    Zhan, Wang
    Chen, Le
    Gu, Zhaozhan
    Jiang, Juncheng
    ENERGY REPORTS, 2020, 6 : 693 - 697
  • [29] Fire Retardant Polymeric Materials '97 - Preface
    Price, D
    POLYMER DEGRADATION AND STABILITY, 1999, 64 (03) : 351 - 352
  • [30] Examination of the effect of fire retardant materials on timber
    Lubloy, Eva
    Takacs, Lajos Gabor
    Enczel, David Istvan
    Cimer, Zsolt
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2021, 12 (04) : 429 - 445