摘要
Two-point gradient echo methods are practical means for estimating T1 value in magnetic-resonance (MR) imaging. Meanwhile, the inhomogeneity of the transmitted B1 field and the imperfect slice profile severely distorts the estimated T1 value. We propose a method for an accurate T1 measurement compensating the inhomogeneity of the B1 field and the effects of the imperfect slice profile. Three MR images of a whole human brain were obtained by multisliced spoiled gradient echo sequences on a 1.5-T scanner with different repetition times and flip angles to calculate the quantitative T1 maps. The histograms of the T1 maps showed two distinguishable peaks of the white matter (672.9±15.5 ms) and the gray matter (921.1±24.7 ms) of the human brain. The results indicate that the T1 value was properly estimated compensating the B1 field inhomogeneity and the slice profile imperfection. The proposed method is applicable to images obtained on any scanners with different parameters, because the method needs neither the information of the flip angle calibrations nor the phantom data to compensate the B1 field inhomogeneity. © 2005 American Institute of Physics.
引用
收藏
相关论文
共 50 条
  • [41] INVIVO MEASUREMENTS OF THE T1 RELAXATION PROCESSES IN THE BONE-MARROW IN PATIENTS WITH MYELODYSPLASTIC SYNDROME - A MAGNETIC-RESONANCE IMAGING STUDY
    JENSEN, KE
    NIELSEN, H
    THOMSEN, C
    SORENSEN, PG
    KARLE, H
    CHRISTOFFERSEN, P
    HENRIKSEN, O
    ACTA RADIOLOGICA, 1989, 30 (04) : 365 - 368
  • [42] MAGNETIC-RESONANCE OF THE CHEST - INITIAL EXPERIENCE WITH IMAGING AND INVIVO T1 AND T2 CALCULATIONS
    ROSS, JS
    ODONOVAN, PB
    NOVOA, R
    MEHTA, A
    BUONOCORE, E
    MACINTYRE, WJ
    GOLISH, JA
    AHMAD, M
    RADIOLOGY, 1984, 152 (01) : 95 - 101
  • [43] THE EFFECT OF SELENIUM SUPPLEMENTATION ON THE NMR PROTON RELAXATION-TIME T1 IN PLASMA
    TURAN, B
    YILMAZ, A
    DALAY, N
    SPECTROSCOPY LETTERS, 1992, 25 (08) : 1405 - 1410
  • [44] Use of Multiple-Tube Phantom: A Method to Globally Correct Native T1 Relaxation Time Inhomogeneity in Dedicated Molecular Magnetic Resonance Breast Coil
    Negi, Pradeep
    Mehta, Shashi Bhushan
    Jena, Amarnath
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (01) : 41 - 46
  • [45] NMR IMAGING OF ADHESIVE-BONDED STRUCTURES - THE USE OF THE T1 AND T2 RELAXATION-TIME INFORMATION
    NIEMINEN, AOK
    LIU, JW
    KOENIG, JL
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1989, 3 (06) : 455 - 462
  • [47] B1 and T1 Mapping of the Breast with a Reference Tissue Method
    Pineda, Federico D.
    Medved, Milica
    Fan, Xiaobing
    Karczmar, Gregory S.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1565 - 1573
  • [48] TriTone:: a radiofrequency field (B1)-insensitive T1 estimator for MRI at high magnetic fields
    Fleysher, Roman
    Fleysher, Lazar
    Liu, Songtao
    Gonen, Oded
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 781 - 789
  • [49] Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis -: A quantitative T1 relaxation time mapping approach
    Vaithianathar, L
    Tench, CR
    Morgan, PS
    Constantinescu, CS
    JOURNAL OF NEUROLOGY, 2003, 250 (03) : 307 - 315
  • [50] Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths
    Dobre, Mircea C.
    Ugurbil, Kamil
    Marjanska, Malgorzata
    MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 733 - 735