The measurement of residual urine volume by electrical impedance in man

被引:0
|
作者
Doyle, P.T. [1 ]
Hill, D.W. [1 ]
机构
[1] Inst. Urol., Univ. London, Shaftesbury Hosp., London, United Kingdom
来源
| 1975年 / 13卷 / 02期
关键词
ELECTRIC MEASUREMENTS - Impedance;
D O I
暂无
中图分类号
学科分类号
摘要
J. C. Denniston and L. E. Baker have reported a linear relationship between the electrical impedance at 100 kHz measured between electrodes placed close to the umbilicus and on the pubis in anaesthetised dogs and the volume of urine present in the bladder. They pointed out that this simple, non-invasive, technique for the monitoring of the urinary bladder content would be of value in post-surgical patients and in paraplegics as an index of renal function and urinary statis. They did not, however, report any actual experience with the method in conscious man. For this reason, it was decided to investigate the method proposed by Denniston and Baker in regard to its applicability both in conscious patients those under a general anaesthetic. It was further decided to fill the bladder with physiological saline since this fluid is routinely used in bladder volume investigations. When the bladder was being filled, a linear decrease in impedance with bladder volume was nearly always observed. However, when the bladder was emptied in all conscious patients and one out of three anaesthetised patients, the final value of the abdominal impedance did not correspond with the measured residual volume. The present authors therefore conclude that the method proposed by Denniston and Baker cannot be recommended for the routine determination of residual urine volumes. The patients must also remain in exactly the same position; otherwise the value of impedance may be altered.
引用
收藏
页码:307 / 308
相关论文
共 50 条
  • [41] INTRAVENTRICULAR VOLUME MEASUREMENT WITH IMPEDANCE CATHETER
    BAAN, J
    KERKHOF, PLM
    VANDIJK, AD
    VANDERVELDE, ET
    CIRCULATION, 1980, 62 (04) : 290 - 290
  • [42] ULTRASOUND MEASUREMENT OF URINE VOLUME - REPLY
    MASSAGLI, TL
    JAFFE, KM
    CARDENAS, DD
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1990, 32 (10): : 928 - 928
  • [43] Neck electrical impedance for measurement of swallowing
    Yamamoto, Y
    Nakamura, T
    Seki, Y
    Utsuyama, K
    Akashi, K
    Jikuya, K
    ELECTRICAL ENGINEERING IN JAPAN, 2000, 130 (04) : 35 - 44
  • [44] MEASUREMENT OF PLEURAL EFFUSION BY ELECTRICAL IMPEDANCE
    DENNISTON, JC
    BAKER, LE
    JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (05) : 851 - 857
  • [45] MEASUREMENT OF TRANSTHORACIC ELECTRICAL-IMPEDANCE
    THOMAS, AN
    VOHRA, A
    POLLARD, BJ
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 66 (06) : 733 - 734
  • [46] A Measurement System for Electrical Impedance Tomography
    Kriz, T.
    Roubal, Z.
    Rez, J.
    PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 905 - 909
  • [47] Measurement system for electrical impedance and EGG
    Li, Zhangyong
    He, Zhonghua
    Wang, Wei
    Ren, Chaoshi
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 290 - +
  • [48] Measurement of Post-Void Residual Urine
    Asimakopoulos, Anastasios D.
    De Nunzio, Cosimo
    Kocjancic, Ervin
    Tubaro, Andrea
    Rosier, Peter F.
    Finazzi-Agro, Enrico
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 (01) : 55 - 57
  • [49] Indirect measurement of lung density and air volume from Electrical Impedance Tomography (EIT) data
    Brown, B. H.
    Milnes, P.
    Mills, G. H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3897 - +
  • [50] Noninvasive measurement of stroke volume changes in critically ill patients by means of electrical impedance tomography
    Fabian Braun
    Martin Proença
    Anna Wendler
    Josep Solà
    Mathieu Lemay
    Jean-Phillipe Thiran
    Norbert Weiler
    Inéz Frerichs
    Tobias Becher
    Journal of Clinical Monitoring and Computing, 2020, 34 : 903 - 911