Profile analysis in asymmetric powder diffraction with parallel beam geometry and curved position sensitive detector

被引:0
|
作者
ENSCI, Limoges, France [1 ]
机构
来源
Materials Science Forum | 1998年 / 278-281卷 / Pt 1期
关键词
Detectors - Gels - Monochromators - Nanostructured materials - Thermal noise - Titanium dioxide - Transparency;
D O I
暂无
中图分类号
学科分类号
摘要
The instrumental function of a high resolution asymmetric X-rays diffraction equipment was investigated. The broadening contributions of focal spot size, monochromator, specimen transparency, geometrical effects and thermal noise of the position sensitive detector were analyzed and convoluted to synthesize the line profile shapes on a wide angular range, Taking into account the real instrumental function, the anisotropic shape of TiO2 aerogels nano-crystals was determined by line profile analysis and whole pattern fitting.
引用
收藏
页码:115 / 120
相关论文
共 50 条
  • [41] Measurement and analysis of field-induced crystallographic texture using curved position-sensitive diffraction detectors
    Hugh Simons
    John E. Daniels
    Andrew J. Studer
    Jacob L. Jones
    Mark Hoffman
    Journal of Electroceramics, 2014, 32 : 283 - 291
  • [42] Evaluation of the divergence of a thermal neutron beam using a position sensitive detector
    de Almeida, GL
    Silvani, MI
    Furieri, RCAA
    Goncalves, MJ
    Lopes, RT
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 771 - 774
  • [43] A NEW LINEAR POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRON POWDER DIFFRACTOMETRY
    SCHAFER, W
    JANSEN, E
    ELF, F
    WILL, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (JUN) : 159 - 166
  • [44] Instrumentation for Position Sensitive Detector-Powder Diffractometer at CENM-Maamora
    Messous, M. Y.
    Belhorma, B.
    Labrim, H.
    El Bakkari, B.
    Jabri, H.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [45] DETECTION OF FATIGUE DAMAGE BY THE USE OF POSITION-SENSITIVE DETECTOR - SINGULARITY OF CHANGE IN X-RAY DIFFRACTION PROFILE.
    Kohno, Tadao
    Fujimoto, Hiroyuki
    Kohara, Masayoshi
    Zairyo/Journal of the Society of Materials Science, Japan, 1986, 35 (394) : 737 - 742
  • [46] POSITION-SENSITIVE PARALLEL PLATE AVALANCHE DETECTOR (PPAD) FOR FISSION FRAGMENTS
    JUST, M
    HABS, D
    METAG, V
    SPECHT, HJ
    NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (02): : 283 - 289
  • [47] A PARALLEL ELECTRODE POSITION-SENSITIVE DETECTOR SYSTEM FOR HIGH COUNTING RATES
    HENDRIX, J
    LENTFER, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 246 - 250
  • [48] PERFORMANCE OF PARALLEL-PLATE ELECTRON SPECTROMETER WITH POSITION-SENSITIVE DETECTOR
    YAGISHITA, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1986, 25 (05): : 657 - 660
  • [49] Neutron Diffraction Studies of a Fully Asymmetric Diffraction Geometry of a Bent Perfect Crystal with the Output Beam Compression
    Mikula, P.
    Vrana, M.
    Saroun, J.
    Em, V.
    Capek, J.
    ACTA PHYSICA POLONICA A, 2016, 130 (04) : 1114 - 1117
  • [50] Analysis of focused-beam powder X-ray diffraction resolution using doubly curved crystal optics
    Bingoelbali, A.
    MacDonald, C. A.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 : 715 - 723