Measurements of the particle size distribution of meta powders using a Coulter Counter do not always give reliable results. The conventional instrument exhibits for this purpose some basic shortcomings in the design of the orifice tube. This paper shows that some particles were counted several times, resulting in erratic countings. Moreover, when sizing conducting particles, the usual equation expressing the relationship between particle diameter and pulse height has to be modified. A modified orifice tube is proposed. Other improvements such as screening of the sample beaker and homogenization of the suspension of metal particles are also discussed.
引用
收藏
页码:56 / 61
相关论文
共 50 条
  • [41] GRAY-CODE BIDIRECTIONAL COUNTER.
    Gonchar, A.I.
    Nesterenko, V.S.
    Fazkullin, V.A.
    Instruments and experimental techniques New York, 1982, 25 (5 pt 1): : 1135 - 1136
  • [42] Directional measurement of cosmic radiation with a counter.
    Tuwim, L
    SITZUNGSBERICHTE DER PREUSSICHEN AKADEMIE DER WISSENSCHAFTEN PHYSIKALISCH-MATHEMATISCHE KLASSE, 1931, : 91 - U21
  • [43] The examination of mitogenetic radiation with the GM counter.
    Barth, H.
    NATURWISSENSCHAFTEN, 1935, 23 : 688 - 688
  • [44] USING FIGURES FROM COULTER-S COUNTER
    SUMMERS, GAC
    JOURNAL OF CLINICAL PATHOLOGY, 1976, 29 (11) : 1045 - 1045
  • [45] Experimental characterization of a metal-oxide-semiconductor field-effect transistor-based Coulter counter
    Sridhar, Manoj
    Xu, Dongyan
    Kang, Yuejun
    Hmelo, Anthony B.
    Feldman, Leonard C.
    Li, Dongqing
    Li, Deyu
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (10)
  • [46] Note on the use of a thyratron with a Geiger counter.
    de Bruyne, NA
    Webster, HC
    PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1931, 27 : 113 - 115
  • [47] GP-IB UNIVERSAL COUNTER.
    Shibata, Hiroshi
    National technical report, 1981, 27 (01): : 25 - 31
  • [48] Improvements to the "scale of two" thyratron counter.
    Lewis, WB
    PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1934, 30 : 543 - 548
  • [49] Experimental characterization of a metal-oxide-semiconductor field-effect transistor-based Coulter counter
    Sridhar, Manoj
    Xu, Dongyan
    Kang, Yuejun
    Hmelo, Anthony B.
    Feldman, Leonard C.
    Li, Dongqing
    Li, Deyu
    Journal of Applied Physics, 2008, 103 (10):
  • [50] REALIZATION OF A HIGH SENSITIVITY NEUTRON REM COUNTER.
    Nakamura, Takashi
    Hara, Akihisa
    Suzuki, Toshikazu
    Nuclear instruments and methods in physics research, 1985, A241 (2-3): : 554 - 560