Active Contours: An overview with applications to motion artifact cancellation in MRI

被引:0
|
作者
Guidry, Diana L. [1 ]
Farag, Aly A. [1 ]
机构
[1] Univ of Louisville, Louisville, United States
关键词
Data acquisition - Image analysis - Image quality - Magnetic resonance imaging - Motion compensation;
D O I
暂无
中图分类号
学科分类号
摘要
Motion can be estimated by detecting the edges of a moving object using Active Contours, and registering them together to obtain the motion model parameters. This idea can be applied to patient motion during the acquisition of an MRI to eliminate motion artifacts in the image. The data obtained during the MRI acquisition, the k-space, can be divided into several subbands such that each subband is acquired in a small fraction of the full imaging time. These subbands create invariant tissue feature maps called subband images. Using Active Contours, the relative motion is analyzed across the different subband images to determine the motion parameters. Using these motion parameters it is possible to correct the subbands, thus correcting the k-space. This has the potential to yield clear, noise-free MR images.
引用
收藏
页码:3425 / 3428
相关论文
共 50 条
  • [21] Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering
    Izzetoglu, Meltem
    Chitrapu, Prabhakar
    Bunce, Scott
    Onaral, Banu
    BIOMEDICAL ENGINEERING ONLINE, 2010, 9
  • [22] COMPARATIVE AND EVALUATIVE THE ADAPTIVE FILTER IN MOTION ARTIFACT CANCELLATION OF PULSE OXIMETRY
    Kunchon, Sitthi
    Desudchit, Tayard
    Chinrungrueng, Chedsada
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 195 - +
  • [23] An Improved Algorithm of Translational Motion Artifact Correction for MRI
    Wu Chunli
    Du Zhibing
    Yuan Kun
    Wei Yun
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4054 - 4057
  • [24] MOTION ARTIFACT CORRECTION IN MRI USING GENERALIZED PROJECTIONS
    HEDLEY, M
    HONG, Y
    ROSENFELD, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) : 40 - 46
  • [25] Mitigating head motion artifact in functional connectivity MRI
    Ciric, Rastko
    Rosen, Adon F. G.
    Erus, Guray
    Cieslak, Matthew
    Adebimpe, Azeez
    Cook, Philip A.
    Bassett, Danielle S.
    Davatzikos, Christos
    Wolf, Daniel H.
    Satterthwaite, Theodore D.
    NATURE PROTOCOLS, 2018, 13 (12) : 2801 - 2826
  • [26] An improved algorithm for rotational motion artifact suppression in MRI
    Weerasinghe, C
    Yan, H
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) : 310 - 317
  • [27] Motion artifact reduction in MRI through generalized DFT
    Knutsson, H
    Andersson, M
    Wigström, L
    Borga, M
    Sigfridsson, A
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 896 - 899
  • [28] Principles and applications of active noise cancellation
    Van, Laere, L.
    Sas, P.
    Proceedings - International Conference on Noise Control Engineering, 1988,
  • [29] Mitigating head motion artifact in functional connectivity MRI
    Rastko Ciric
    Adon F. G. Rosen
    Guray Erus
    Matthew Cieslak
    Azeez Adebimpe
    Philip A. Cook
    Danielle S. Bassett
    Christos Davatzikos
    Daniel H. Wolf
    Theodore D. Satterthwaite
    Nature Protocols, 2018, 13 : 2801 - 2826
  • [30] Unsupervised MRI motion artifact disentanglement: introducing MAUDGAN
    Safari, Mojtaba
    Yang, Xiaofeng
    Chang, Chih-Wei
    Qiu, Richard L. J.
    Fatemi, Ali
    Archambault, Louis
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):