Seismic evaluation and retrofit of damaged R/C buildings

被引:0
|
作者
Sucuoglu, Haluk [1 ]
Gur, Türel [1 ]
Gulkan, Polat [1 ]
机构
[1] Middle East Technical University, Department of Civil Engineering, Earthquake Engineering Research Center, Ankara, Turkey
关键词
Earthquake resistance - Failure analysis - Retrofitting - Seismology - Structural analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A severe earthquake measuring Ms 6.2 occurred near the city of Ceyhan (population 100 000) in Southern Turkey on 27 June 1998. Although the focal distance to Ceyhan was 32 km, fault rupture was directed towards Ceyhan, causing heavy damage in the city as a result of a strong motion with a PGA of 0.28 g. Out of a total number of 146 casualties, 86 were in Ceyhan. Twelve R/C buildings collapsed and 120 were classified as moderately damaged in Ceyhan. These 120 multistory buildings have been inspected and their seismic retrofit projects have been prepared by the Earthquake Engineering Research Center of the Middle East Technical University (METU/EERC). The retrofit works include detailed damage assessment and structural evaluation of the existing buildings, selection of the retrofit scheme, and final performance verification by the capacity spectrum method. Cast in place concrete infill walls are employed as the primary elements of seismic retrofit. The selected retrofit scheme has provided the required seismic safety and economy.
引用
收藏
页码:97 / 110
相关论文
共 50 条
  • [21] Advanced Seismic Retrofit of a Mixed R/C-Steel Structure
    Terenzi, Gloria
    Bazzani, Caterina
    Costoli, Iacopo
    Sorace, Stefano
    Spinelli, Paolo
    BUILDINGS, 2019, 9 (12)
  • [22] Seismic retrofit of R/C frames with CFRP overlays - Experimental results
    Ozden, S
    Akguzel, U
    Ozturan, T
    SEISMIC ASSESSMENT AND REHABILITATION OF EXISTING BUILDINGS, 2003, 29 : 357 - 382
  • [23] Seismic retrofit for rectangular R/C columns by steel and CF jackets
    Yoshimura, K
    Kikuchi, K
    Kuroki, M
    Wang, JH
    Itai, T
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 1131 - 1137
  • [24] Seismic retrofit of church buildings through base isolation
    De Luca, A
    Mele, E
    Giagnuolo, C
    STRUCTURAL CONTROL FOR CIVIL AND INFRASTRUCTURE ENGINEERING, 2001, : 119 - 126
  • [25] A Seismic Retrofit Cost Database for Buildings with a Framed Structure
    Jafarzadeh, Reza
    Ingham, Jason M.
    Wilkinson, Suzanne
    EARTHQUAKE SPECTRA, 2014, 30 (02) : 625 - 637
  • [26] Seismic retrofit of existing buildings through the dissipative columns
    Castaldo, Paolo
    Palazzo, Bruno
    Perri, Francesco
    Marino, Ivana
    Faraco, Marco Maria
    ECCOMAS Congress 2016 - Proceedings of the 7th European Congress on Computational Methods in Applied Sciences and Engineering, 2016, 4 : 8445 - 8459
  • [27] Dissipative steel exoskeletons for seismic retrofit of RC buildings
    Massimiliano Ferraioli
    Osvaldo Pecorari
    Salvatore Mottola
    Angela Diana
    Archives of Civil and Mechanical Engineering, 25 (3)
  • [28] Reducing the Seismic Vulnerability of Existing Buildings: Assessment and Retrofit
    Ferreira, Tiago Miguel
    Mendes, Nuno
    Silva, Rui
    BUILDINGS, 2019, 9 (06)
  • [29] Supplemental Vertical Support as a Means for Seismic Retrofit of Buildings
    Comartin, Craig D.
    SEISMIC RISK ASSESSMENT AND RETROFITTING: WITH SPECIAL EMPHASIS ON EXISTING LOW-RISE STRUCTURES, 2009, 10 : 329 - 342
  • [30] Seismic and energy integrated retrofit of buildings: A critical review
    Ademovic, Naida
    Formisano, Antonio
    Penazzato, Luca
    Oliveira, Daniel V.
    FRONTIERS IN BUILT ENVIRONMENT, 2022, 8