PERFORMANCE EVALUATION FOR BUFFER-CONTAINED DISK UNITS.

被引:0
|
作者
Mitsuishi, Akitoshi [1 ]
Mizoguchi, Tetsuo [1 ]
Miyachi, Taizo [1 ]
机构
[1] Mitsubishi Electric Corp, Kamakura, Jpn, Mitsubishi Electric Corp, Kamakura, Jpn
关键词
COMPUTER SIMULATION - DATA STORAGE; MAGNETIC; -; Disk;
D O I
暂无
中图分类号
学科分类号
摘要
The rotation delay of a disk caused by RPS-miss, which is larger than usually assumed, is nonnegligible in systems of heavy load. A method is proposed to cope with this delay by improving the response time and throughput: a buffer-contained disk unit. Its performance evaluation is shown by simulation. The buffer-contained disk unit has a small amount of buffer (some tens of kB). Data transmission between a buffer and a disk control unit and disk rotation occur asynchronously, which considerably reduces the delay time. In writing operation, the seek time is overlapped by data transmission time, and seek and rotation delay time appear to be zero. In simulation, an access pattern of real system is used which is obtained by tracing the disk input/output operation. Hence, the response and throughput are clearly improved. The method can be applied to a large variety of disks with great performance improvement and little add-on hardware.
引用
收藏
页码:32 / 40
相关论文
共 50 条
  • [21] Thermal stress performance of glazed units contained phase change material
    Zhou, Yingming
    Wu, Guozhong
    Wang, Shuwei
    Huang, Bo
    Wang, Fengshun
    Wang, Zemei
    ENERGY EXPLORATION & EXPLOITATION, 2021, 39 (06) : 1973 - 1992
  • [22] Evaluation of polymerization contraction forces of composite resins using halogen and LED light curing units.
    Castañeda-Espinosa, JC
    Mondelli, RFL
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 129 - 129
  • [23] Evaluation of care conditions in intensive care units. Results of an online questionnaire of critical care nurses
    Isfort, M.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2017, 112 (06) : 543 - 549
  • [24] Clincal implementation and evaluation of hepatitis C virus (HCV) RNA quantification using international units.
    Erali, M
    Konnick, E
    Villnave, K
    Ashwood, ER
    Hillyard, DR
    HEPATOLOGY, 2000, 32 (04) : 274A - 274A
  • [25] COMPARISON OF TWO METHODS FOR THE SUBJECTIVE EVALUATION OF TELEVISION PICTURES. REPRESENTATION OF THE RESULTS IN COMMON UNITS.
    Sallio, P.
    Kretz, F.
    EBU Technical Review, 1982, (192): : 59 - 69
  • [26] SEISMIC PERFORMANCE OF TWO FULL SIZE REINFORCED CONCRETE BEAM-COLUMN JOINT UNITS.
    Blakeley, R.W.G.
    Megget, L.M.
    Priestley, M.J.N.
    Bulletin of the New Zealand Society for Earthquake Engineering, 1975, 8 (01): : 38 - 69
  • [27] Evaluation of buffer materials for fluorine contained solid phase epitaxy of 123 films on MgO substrates
    Yamamoto, Y
    Mukaida, M
    Ichinose, A
    Matsumoto, K
    Yoshida, Y
    Horii, S
    Saito, A
    Ohshima, S
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2004, 412 : 1316 - 1320
  • [28] Evaluation and Performance Modeling of a Burst Buffer Solution
    Schenck, Wolfram
    El Sayed, Salem
    Foszczynski, Maciej
    Homberg, Wilhelm
    Pleiter, Dirk
    OPERATING SYSTEMS REVIEW, 2016, 50 (02) : 12 - 26
  • [29] Amphisbaena: A Novel Persistent Buffer Management Strategy to Improve SMR Disk Performance
    Zhang, Chi
    Yu, Fangxing
    Nie, Shiqiang
    Tang, Wei
    Liu, Fei
    Liu, Song
    Wu, Weiguo
    APPLIED SCIENCES-BASEL, 2024, 14 (02):