The elastic modulus of dentine determined by static and dynamic methods

被引:40
|
作者
Rees, J.S. [1 ]
Jacobsen, P.H. [1 ]
Hickman, J. [1 ]
机构
[1] Department of Conservative Dentistry, University Wales College of Medicine, Heath Park, Cardiff CF4 4XY, United Kingdom
来源
Clinical Materials | 1994年 / 17卷 / 01期
关键词
Dental amalgams - Elastic moduli - Finite element method - Testing;
D O I
10.1016/0267-6605(94)90042-6
中图分类号
学科分类号
摘要
The purpose of this investigation was to determine a static elastic modulus of dentine using a three point beam test and a dynamic modulus in the frequency range of 0.1 Hz and 10 Hz across a temperature range of 27-37°C. At body temperature, the mean static modulus was 8.6 GPa, (standard deviation 0.86 GPa). The dynamic test produced a range of modulus values. At 0.1 Hz the modulus ranged from 14.3 to 15.2 GPa; for 1.0 Hz the range was 14.6-15.5 GPa and for 10 Hz the range was 14.9-15.8 GPa. The results are of value in the design and analysis of restorative materials.
引用
收藏
页码:11 / 15
相关论文
共 50 条
  • [31] Elastic modulus and hardness of muscovite and rectorite determined by nanoindentation
    Zhang, Guoping
    Wei, Zhongxin
    Ferrell, Ray E.
    APPLIED CLAY SCIENCE, 2009, 43 (02) : 271 - 281
  • [32] The elastic modulus of Matrigel™ as determined by atomic force microscopy
    Soofi, Shauheen S.
    Last, Julie A.
    Liliensiek, Sara J.
    Nealey, Paul F.
    Murphy, Christopher J.
    JOURNAL OF STRUCTURAL BIOLOGY, 2009, 167 (03) : 216 - 219
  • [33] The effect of confining pressure on elastic wave velocities and dynamic to static Young's modulus ratio
    Asef, Mohammad Reza
    Najibi, Ali Reza
    GEOPHYSICS, 2013, 78 (03) : D135 - D142
  • [34] Elastic Modulus Determination of Transgenic Aspen Using a Dynamic Mechanical Analyzer in Static Bending Mode
    Horvath, Balazs
    Peszlen, Ilona
    Peralta, Perry
    Horvath, Laszlo
    Kasal, Bohumil
    Li, Laigeng
    FOREST PRODUCTS JOURNAL, 2010, 60 (03) : 296 - 300
  • [35] COMPARISON OF PARTITION COEFFICIENTS DETERMINED BY STATIC AND DYNAMIC METHODS ON POROUS GLASS BEADS
    GRUBISICGALLOT, Z
    BENOIT, H
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1971, 9 (05) : 262 - +
  • [36] INTERPRETATION OF THE DIFFERENCE IN THE SURFACE-DIFFUSION COEFFICIENTS DETERMINED BY DYNAMIC AND STATIC METHODS
    IKUMA, Y
    KOMATSU, W
    SOLID STATE IONICS, 1988, 26 (02) : 161 - 161
  • [37] INTERPRETATION OF THE DIFFERENCE IN SURFACE-DIFFUSION COEFFICIENTS DETERMINED BY DYNAMIC AND STATIC METHODS
    IKUMA, Y
    KOMATSU, W
    SOLID STATE IONICS, 1989, 32-3 : 946 - 949
  • [38] THE DYNAMIC ELASTIC MODULUS OF THE ARTERIAL WALL
    BERGEL, DH
    JOURNAL OF PHYSIOLOGY-LONDON, 1960, 151 (03): : P26 - P27
  • [39] Dynamic elastic modulus of 'packable' composites
    Abe, Y
    Lambrechts, P
    Inoue, S
    Braem, MJA
    Takeuchi, M
    Vanherle, G
    Van Meerbeek, B
    DENTAL MATERIALS, 2001, 17 (06) : 520 - 525
  • [40] Comparison of static and dynamic methods for measuring stiffness of high modulus steels and metal composites
    Lord, J. D.
    Morrell, R. M.
    CANADIAN METALLURGICAL QUARTERLY, 2014, 53 (03) : 292 - 299