SPECTROMETRIC MEASUREMENT AND SIGNAL PROCESSING MODULE OF SEMICONDUCTOR DETECTORS.

被引:0
|
作者
Mazurov, I.B.
Sibiryak, Yu.G.
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A spectrometric module is described that is intended to operate with a charge-sensitive preamplifier in investigations of medium and high-energy charged particles for input charges to 10**5 impulses/sec. Utilization of a time-varying filter as shaper permitted an approximately 6 times diminution in the duration of the shaped pulse as compared with the pulse formed by a CR-RC filter under identical noise resolution. The signal at the module output is rectangular with a 100-nsec front and decay duration and a maximum 10-v amplitude.
引用
收藏
页码:848 / 851
相关论文
共 50 条
  • [1] SPECTROMETRIC MEASUREMENT AND SIGNAL-PROCESSING MODULE OF SEMICONDUCTOR-DETECTORS
    MAZUROV, IB
    SIBIRYAK, YG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (04) : 848 - 851
  • [2] FORMATION OF A SIGNAL IN SEMICONDUCTOR DETECTORS.
    Eremin, V.K.
    Strokan, N.B.
    Tisnek, N.I.
    1972, 6 (05): : 833 - 835
  • [3] A Digital Signal Processing Module for Ge Semiconductor Detectors
    Fukuchi, Tomonori
    Arai, Youichi
    Watanabe, Fusao
    Motomura, Shinji
    Takeda, Shin'ichiro
    Kanayama, Yousuke
    Haba, Hiromitsu
    Watanabe, Yasuyoshi
    Enomoto, Shuichi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (02) : 461 - 467
  • [4] Semiconductor Nuclear Detectors.
    Schaub, Bernard
    Onde Electrique, 1976, 56 (02): : 51 - 53
  • [5] PROGRESS IN SEMICONDUCTOR DRIFT DETECTORS.
    Rehak, Pavel
    Walton, Jack
    Gatti, Emillo
    Longoni, Antonio
    Sanpietro, Marco
    Kemmer, Josef
    Dietl, Hans
    Holl, Peter
    Klanner, Robert
    Lutz, Gerhard
    Wylie, Andrew
    Becker, Hubert
    Nuclear instruments and methods in physics research, 1986, A248 (2-3): : 367 - 378
  • [6] SPECTROMETRIC PROPERTIES OF CdTe NUCLEAR RADIATION DETECTORS.
    Kalugina, L.I.
    Pavlova, G.S.
    Mitin, V.I.
    Rodionov, Yu.F.
    Kireev, I.S.
    Vanyukov, A.V.
    1600, (05):
  • [7] OPTIMUM ETCHNING OF A PHOSPHATE GLASS SPECTROMETRIC DETECTORS.
    Kopchenov, V.E.
    Nikolaev, V.A.
    Nuclear tracks, 1986, 11 (4-5): : 221 - 227
  • [8] SIGNAL-PROCESSING FOR SEMICONDUCTOR-DETECTORS
    GOULDING, FS
    LANDIS, DA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (03) : 1125 - 1141
  • [9] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS.
    Radeka, V.
    Nuclear instruments and methods in physics research, 1983, 226 (01): : 209 - 218
  • [10] CHARGE LOSSES IN DENSE TRACKS IN SEMICONDUCTOR DETECTORS.
    Eremin, V.K.
    Strokan, N.B
    Tisnek, N.I.
    Soviet Physics, Semiconductors (English translation of Fizika i Tekhnika Poluprovodnikov), 1976, 10 (01): : 33 - 36