Purity in room temperature liquid ionization chambers

被引:0
|
作者
Ochsenbein, S. [1 ]
Schinzel, D. [1 ]
Gonidec, A. [1 ]
Schmidt, W.F. [1 ]
机构
[1] SIN, Switzerland
来源
关键词
Electric Fields - Electrons--Transport Properties - Organic Compounds;
D O I
暂无
中图分类号
学科分类号
摘要
Electron attaching impurities in the liquids TMS (tetramethylsilane) and TMP (2,2,4,4 tetramethylpentane) have been removed to a high degree with efficient and fast purification methods. Free electron lifetimes of 450 and 77 μs have been measured for the two liquids respectively.
引用
收藏
页码:654 / 656
相关论文
共 50 条
  • [31] SPECTROMETRIC PROPERTIES OF CYLINDRICAL LIQUID-XENON IONIZATION CHAMBERS
    KIRSANOV, MA
    KRUGLOV, AA
    OBODOVSKII, IM
    POKACHALOV, SG
    SHILOV, VA
    VORONOVA, TY
    RAZINOVA, IG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (01) : 66 - 69
  • [32] Plastic deformation of high purity magnesium at room temperature
    Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji-shi, Hyogo 671-2201
    不详
    不详
    Keikinzoku J Jpn Inst Light Met, 2006, 12 (711-715):
  • [33] Ductile fracture of commercial purity titanium at room temperature
    Shatil, G
    Smith, DJ
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2000, 23 (10) : 825 - 833
  • [34] Room Temperature Liquid Porphyrins
    Maruyama, Sumio
    Sato, Kenta
    Iwahashi, Hiroyuki
    CHEMISTRY LETTERS, 2010, 39 (07) : 714 - 716
  • [35] Liquid metals AT ROOM TEMPERATURE
    Dickey, Michael D.
    PHYSICS TODAY, 2021, 74 (04) : 30 - 36
  • [36] PROPERTIES OF LIQUID IONIZATION CHAMBERS AT LDR BRACHYTHERAPY DOSE-RATES
    JOHANSSON, B
    WICKMAN, G
    HOLMSTROM, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (04): : 575 - 587
  • [37] LIQUID-ARGON IONIZATION CHAMBERS AS TOTAL-ABSORPTION DETECTORS
    WILLIS, WJ
    RADEKA, V
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (02): : 221 - 236
  • [38] LIQUID IONIZATION CHAMBERS WITH ELECTRON EXTRACTION AND MULTIPLICATION IN THE GASEOUS PHASE.
    Anderson, D.F.
    Charpak, G.
    Holroyd, R.A.
    Lamb, D.C.
    Nuclear instruments and methods in physics research, 1987, A261 (03): : 445 - 448
  • [39] LIQUID IONIZATION CHAMBERS WITH ELECTRON EXTRACTION AND MULTIPLICATION IN THE GASEOUS-PHASE
    ANDERSON, DF
    CHARPAK, G
    HOLROYD, RA
    LAMB, DC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (03): : 445 - 448
  • [40] HIGH RATE OPERATION OF WARM-LIQUID IONIZATION CHAMBERS.
    Anderson, D.F.
    Holroyd, R.A.
    Nuclear instruments and methods in physics research, 1987, A260 (2-3): : 343 - 345